MYDCOMBI Dailymed
Generic: tropicamide and phenylephrine hydrochloride is used for the treatment of Iritis Keratitis Iridocyclitis Mydriasis Fissure in Ano Glaucoma, Open-Angle Hemorrhoids Hypertension Hypotension Pruritus Ani Rhinitis, Vasomotor Shock, Septic Tachycardia, Supraventricular Tachycardia, Ventricular
Go PRO for all pill images
1indications And Usage
MYDCOMBI (tropicamide and phenylephrine hydrochloride ophthalmic spray) 1% / 2.5% is indicated to induce mydriasis for diagnostic procedures and in conditions where short term pupil dilation is desired.
MYDCOMBI is a combination of tropicamide, an anticholinergic, and phenylephrine hydrochloride, an alpha-1 adrenergic receptor agonist indicated to induce mydriasis for diagnostic procedures and in conditions where short term pupil dilation is desired (1 )
2dosage And Administration
- Administer one metered spray to the cornea of each eye to be dilated. Repeat after 5 minutes. (
2.1 )- In pediatric patients younger than 1 year old, administer one metered spray to the cornea of each eye to be dilated, up to a maximum of 3 sprays per eye per day (
2.1 )2.1Recommended Dosage
Administer one metered spray to the cornea of each eye to be dilated. Repeat after 5 minutes.
Pediatric Patients Younger Than 1 Year Old
In pediatric patients younger than 1 year old, administer one metered spray to the cornea of each eye to be dilated, up to a maximum of 3 sprays per eye per day.
2.2Administration Instructions
The following steps should be followed sequentially:
- Load the MYDCOMBI dispenser by depressing the FILL BUTTON at the top of the dispenser once.
Figure 1: MYDCOMBI Dispenser Front (L) and Back (R) View - Hold MydCombiâ„¢ dispenser with thumb over Mist Button, wrapping other fingers around base.
- Bring MydCombiâ„¢ dispenser to patient's eye with Mirror facing the eye.
– The dispenser should be as close as patient's nose.– To prevent blinking, use your other hand to gently pull lower eyelid down or ask patient to pull her/his lid down.- Aim Mist Opening toward the center of eye.
- Confirm Alignment Marks (on the Fill Button and the cartridge side) align with the center of eye.
If patient is having trouble centering their eye on the blue light, ask that they look up, then look at the BLUE Mirror.
– Ask patient to confirm when their eye is centered on the BLUE Mirror.- Firmly press and release Mist Button.
– The drug solution should gently wet the eye. Repeat steps A to F if needed.- Administer a second metered spray after 5 minutes to each dilated eye.
- Repeat steps A to G for the contralateral eye if it is to be dilated.
3dosage Forms And Strengths
MYDCOMBI is a sterile, clear, colorless, topical ophthalmic spray containing tropicamide 1% (w/w) and phenylephrine hydrochloride 2.5% (w/w). Each metered spray delivers 0.008 mL which contains 0.08 mg tropicamide and 0.2 mg phenylephrine hydrochloride.
Ophthalmic spray containing tropicamide 1% and phenylephrine hydrochloride 2.5%. Each metered spray delivers 0.008 mL which contains 0.08 mg tropicamide and 0.2 mg phenylephrine HCl (3 )
4 Contraindications
- Known hypersensitivity to any component of the formulation (
4.1 )4.1Known Hypersensitivity
Contraindicated in persons showing known hypersensitivity to any component of the formulation.
5warnings And Precautions
- Not for Injection: Topical ophthalmic use (
5.1 )- Significant Elevations in Blood Pressure: Caution in pediatric patients less than 5 years of age, and in patients with cardiovascular disease or hyperthyroidism. In patients at high risk, monitor blood pressure post treatment (
5.2 )- Central Nervous System Disturbances: Caution in pediatric patients where rare incidences of central nervous system disturbances have been reported (
5.3 )- Intraocular Pressure: May produce a transient elevation (
5.4 )- Rebound Miosis: Reported 1 day after administration (
5.5 )5.1Topical Ophthalmic Use
MYDCOMBI is not indicated for injection.
5.2Blood Pressure Elevation
Caution should be exercised with the use of MYDCOMBI in pediatric patients less than 5 years of age and patients with hyperthyroidism, or cardiovascular disease. The post-treatment blood pressure of patients with cardiac and endocrine diseases and any patients who develop symptoms should be carefully monitored.
5.3Central Nervous System Disturbances
Tropicamide in MYDCOMBI may cause CNS disturbances which may be dangerous in pediatric patients. The possibility of psychotic reactions and behavioral disturbances due to hypersensitivity to anticholinergic drugs should be considered.
5.4Intraocular Pressure
Mydriatics may produce a transient elevation of intraocular pressure.
5.5Rebound Miosis
Rebound miosis has been reported one day after receiving phenylephrine hydrochloride ophthalmic solution, and re-administration of the drug produced a lesser mydriatic effect.
6adverse Reactions
Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. The most common adverse reactions (incidence < 2%) were transient blurred vision, reduced visual acuity, photophobia, and mild eye discomfort.
- Most common ocular adverse reactions include transient blurred vision, reduced visual acuity, photophobia, superficial punctate keratitis, and mild eye discomfort. Increased intraocular pressure has been reported following the use of mydriatics (
6.1 )- Systemic adverse reactions including dryness of the mouth, tachycardia, headache, allergic reactions, nausea, vomiting, pallor, central nervous system disturbances and muscle rigidity have been reported with the use of tropicamide (
6.2 )
To report SUSPECTED ADVERSE REACTIONS, contact Eyenovia, Inc. at 1-833-393-6684 or FDA at 1-800-FDA-1088 orwww.fda.gov/medwatch
6.1Ocular Adverse Reactions
Transient blurred vision, reduced visual acuity, photophobia, superficial punctate keratitis, and mild eye discomfort may occur. Increased intraocular pressure has been reported following the use of mydriatics.
6.2Systemic Adverse Reactions
Dryness of the mouth, tachycardia, headache, allergic reactions, nausea, vomiting, pallor, central nervous system disturbances and muscle rigidity have been reported with the use of tropicamide. Psychotic reactions, behavioral disturbances, and vasomotor or cardiorespiratory collapse in children have been reported with the use of anticholinergic drugs.
A marked increase in blood pressure has been reported with the use of phenylephrine, particularly, but not limited to, low weight premature neonates, infants, and hypertensive patients.
7drug Interactions
- Atropine-like Drugs: May exaggerate the adrenergic pressor response (
7.1 )- Cholinergic Agonists and Ophthalmic Cholinesterase Inhibitors: May interfere with the antihypertensive action of carbachol, pilocarpine, or ophthalmic cholinesterase inhibitors (
7.2 )- Potent Inhalation Anesthetic Agents: May potentiate cardiovascular depressant effects of (
7.3 )7.1Agents That May Exaggerate Pressor Responses
Phenylephrine in MYDCOMBI may enhance the pressor effects of atropine-like drugs and induce tachycardia in some patients.
7.2Cholinergic Agonists and Ophthalmic Cholinesterase Inhibitors
Tropicamide in MYDCOMBI may interfere with the antihypertensive action of carbachol, pilocarpine, or ophthalmic cholinesterase inhibitors.
7.3Potent Inhalation Anesthetic Agents
Phenylephrine in MYDCOMBI may potentiate the cardiovascular depressant effects of some inhalation anesthetic agents.
8use In Specific Populations
Pediatric Use: May rarely cause central nervous system disturbances which may be dangerous in pediatric patients (5.3 ,8.4 )
8.1Pregnancy
Risk Summary
There are no available data on MYDCOMBI use in pregnant women or animals to inform any drug-associated risks. It is also not known whether tropicamide or phenylephrine can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. MYDCOMBI should be given to a pregnant woman only if clearly needed.
8.2Lactation
Risk Summary
There are no data on the presence of tropicamide or phenylephrine in human milk from the administration of MYDCOMBI, the effects on the breastfed infant, or the effects on milk production. The developmental and health benefits of breastfeeding should be considered along with the mother's clinical need for MYDCOMBI and any potential adverse effects on the breastfed child from MYDCOMBI.
8.4Pediatric Use
Tropicamide in MYDCOMBI may rarely cause CNS disturbances which may be dangerous in pediatric patients. Psychotic reactions, behavioral disturbances, and vasomotor or cardiorespiratory collapse in children have been reported with the use of anticholinergic drugs [see Warnings and Precautions (5.3)].
8.5Geriatric Use
No overall differences in safety or effectiveness of MYDCOMBI have been observed between patients 65 years of age and older and younger adult patients.
10overdosage
Overdosage of MYDCOMBI may cause a rapid rise in blood pressure. It may also cause headache, anxiety, nausea and vomiting, and ventricular arrhythmias. Prompt injection of a rapidly acting alpha- adrenergic blocking agent such as phentolamine has been recommended.
11description
MYDCOMBI is a sterile, clear, colorless fixed dose combination of an anticholinergic (tropicamide) and an alpha-adrenergic receptor agonist (phenylephrine hydrochloride) for topical ophthalmic use. The 2 active ingredients are represented by the chemical structures below.
Tropicamide:
Chemical Name: Benzeneacetamide, N-ethyl-α-(hydroxymethyl)-N-(4-pyridinylmethyl)-
Molecular Formula: C17H20N2O2
Molecular Weight: 284.35 g/mol
Phenylephrine Hydrochloride:
Chemical Name: (R)-3-hydroxy-α[(methylamino)methyl]benzenemethanol hydrochloride
Molecular Formula: C9H13NO2∙HCl
Molecular Weight: 203.67 g/mol
Each mL of MYDCOMBI ophthalmic spray (sterile) contains: ACTIVES: Phenylephrine Hydrochloride 2.5% (25 mg) equivalent to 20.6 mg of phenylephrine base, Tropicamide 1% (10 mg); INACTIVE: Hydrochloric Acid and/or Sodium Hydroxide may be added to adjust pH (pH 4.8–5.2), Water for Injection; PRESERVATIVE: Benzalkonium Chloride 0.01% (0.1 mg).
12 Clinical Pharmacology
12.1Mechanism of Action
Tropicamide, the anticholinergic component of MYDCOMBI, blocks the responses of the sphincter muscle of the iris, dilating the pupil (mydriasis). Phenylephrine hydrochloride, the alpha-1 adrenergic agonist component of MYDCOMBI, acts as a mydriatic agent by contracting the dilator muscle of the iris.
12.2Pharmacodynamics
MYDCOMBI acts in 15 to 30 minutes with maximal mydriasis occurring in 20 to 90 minutes. Darker irides tend to dilate slower than lightly pigmented irides and to achieve maximal effect may require more doses than lighter irides.
Mydriasis will reverse spontaneously with time, with recovery after 3 to 8 hours. Complete recovery from mydriasis in some individuals may require 24 hours.
13clinical Studies
Two Phase 3 clinical trials were conducted to evaluate the efficacy of MYDCOMBI for achievement of mydriasis. The MIST-1 study was a prospective, double-masked, active-controlled, 3-period cross-over, superiority study to compare the pupil dilating effect of MYDCOMBI to tropicamide 1% and to phenylephrine 2.5%, with all solutions topically administered by the Optejet® Dispenser (N = 64 subjects; 128 eyes). The MIST-2 study was a prospective, multicenter, double-masked, placebo-controlled, 3-period crossover, superiority study to compare the pupil dilating effect of MYDCOMBI to placebo (eyewash solution), with both solutions topically administered by the Optejet Dispenser (N = 70 subjects; 140 eyes).
The primary efficacy endpoint for both studies was the mean change in 35-minute pupil diameter compared to baseline as measured by digital pupillometry in highly photopic conditions. Data from the 2 studies are presented in Table 1. At 35 minutes post-dose, the mean change in pupil diameter was 4.7 mm with MYDCOMBI, 4.1 mm with tropicamide, and 0.9 mm with phenylephrine in MIST-1, and was 4.8 mm with MYDCOMBI and 0.1 mm with placebo in MIST-2. MYDCOMBI was statistically superior to tropicamide administered alone and phenylephrine administered alone.
Table 1 Pupil Size and Change in Diameter from Baseline at 35 Minutes Post-Dose (MIST-1 and MIST-2) (Per-Protocol Population The per-protocol (PP) population included all randomized subjects who received at least one dose of study medication and completed all planned assessments (related to the primary endpoint) without major protocol violations. Two subjects in MIST-1 and one subject in MIST-2 who withdrew consent after their first treatment visit were not included in the PP populations which resulted in 62 completed subjects (124 eyes) in MIST-1 and 69 completed subjects (138 eyes) in MIST-2 comprised the PP populations. Sensitivity analysis performed on the intent-to-treat (ITT) population including all randomized subjects resulted in consistent efficacy results. )MIST-1 MIST-2 Visit MYDCOMBI(N = 124) Tropicamide Alone(N = 124) Phenylephrine Alone(N = 124) MYDCOMBI(N = 138) Placebo(N = 138) SD=Standard Deviation Mean Baseline (SD) 2.6 (0.05) 2.6 (0.05) 2.6 (0.05) 2.6 (0.04) 2.6 (0.04) 35-Minutes Post-Dose (SD) 7.3 (0.08) 6.7 (0.08) 3.5 (0.08) 7.3 (0.07) 2.7 (0.05) Change from Baseline (SD) 4.7 (0.07) 4.1 (0.06) 0.9 (0.08) 4.8 (0.07) 0.1 (0.04) Difference from MYDCOMBI(95% CI) Treatment differences and 95% confidence interval estimates were based on a mixed model including treatment, eye, baseline diameter, and carryover effect (for MIST-2 study only). In both studies, an unstructured covariance structure was used to account for within-subject correlation between eyes. -- 0.6(0.4, 0.8) 3.9(3.7, 4.1) -- 4.7(4.5, 4.8)
MYDCOMBI provided a clinically significant effect in the proportion of eyes achieving pupil diameter of ≥ 6 mm at 35-minute post-dose in 94% of eyes compared to 78% of eyes administered tropicamide alone and 1.6% of eyes administered phenylephrine alone, and 0% of eyes administered placebo. As shown in Figure 2, peak effect was measured at the 80-minute evaluation when the mean change from baseline was 5.2 mm. Treatment differences in mydriasis were observed as early as 20 minutes and still present at 180 minutes post-dose, the end of the protocol-specified observation period.
Figure 2: MIST-1 and MIST-2 pooled, mean pupil diameter vs measurement time, by treatment group. Vertical bars show 95% confidence interval for the mean at each point. Smooth curves are based on an 8 degrees of freedom (df) generalized additive model (GAM) smooth through time, adjusting for baseline pupil diameter. Confidence intervals are not adjusted for correlation.
14how Supplied/storage And Handling
MYDCOMBI is supplied as sterile, clear, colorless solution in a 2 mL vial enclosed in a dispenser cartridge. Each MYDCOMBI cartridge holds approximately 180 sprays.
Do not tamper with or attempt to open the MYDCOMBI cartridge. Such action may damage the dispenser causing an incorrect medication discharge volume; additionally, the dispenser base may not function properly.
Only use the MYDCOMBI cartridge with the MYDCOMBI Dispenser base which may be supplied separately. The MYDCOMBI base will not work with any other cartridges.
NDC 81046-0111-1. Carton containing one replacement sterile drug cartridge
NDC 81046-0111-2. Box containing one carton with one sterile drug cartridge, and one carton with one base unit
NDC 81046-0111-5. Box containing five cartons, each with one replacement sterile drug cartridge
The MYDCOMBI cartridge must be used prior to the expiration date on the cartridge.
STORAGE AND HANDLING SECTION
Storage: Store at room temperature 15°C to 25°C (59°F to 77°F).
Manufactured for Eyenovia, Inc. by Alcami Corporation
15patient Counseling Information
Advise patients that they may experience sensitivity to light and blurred vision while their pupils are dilated.
Advise patients not to drive, use machinery, or do any activity that requires clear vision until they are sure they can perform such activities safely.
Instructions For Use
MydCombiâ„¢(Tropicamide and Phenylephrine HCl Ophthalmic Spray), 1%/2.5%
Rx Only
Contents Getting to know MydCombiâ„¢ 3 How the MydCombiâ„¢ Dispenser Works 3 Understanding the Mist and Battery Lights 4 Important Reminders and Cleaning Instructions 4 Storing the MydCombiâ„¢ Base and Cartridges 5 Assembling the MydCombiâ„¢ Dispenser 6 Preparing MydCombiâ„¢ for Use Each Day 8 Administering MydCombiâ„¢ 9 Troubleshooting Tips 10 Replacing the MydCombiâ„¢ Cartridge 10 Symbols Used in Labels on the MydCombiâ„¢ Cartridge, Base and Packaging 11
INSTRUCTIONS FOR USEMydCombiâ„¢ Ophthalmic Spray
This "Instructions for Use" document has information about the administration of MydCombiâ„¢ (Tropicamide and Phenylephrine HCI Ophthalmic Spray) 1%/2.5%.
MydCombi™ is packaged in a dispenser that mists drug solution onto the eye. It has 2 parts – the cartridge that holds the drug solution, and the base that holds electronics.
Getting to know MydCombiâ„¢
MydCombiâ„¢ Dispenser Parts MydCombiâ„¢ Assembled
How the MydCombiâ„¢ Dispenser Works
- The MydCombiâ„¢ Cartridge holds the drug solution.
- The MydCombiâ„¢ Base supplies power to the dispenser.
- The Fill Button is pressed to load the drug solution for topical ophthalmic administration.
- The Mist Opening is where drug solution comes out when the Mist Button is pressed.
- The Light and Mirror around the Mist Opening and the Eye Alignment Marks on the top and each side of the cartridge help align the eye for drug administration.
- The Battery Light shows how much electrical charge remains in the Base.
- The Release Tabs on each side of the cartridge are used to separate the cartridge and base when replacing cartridges.
- The MydCombiâ„¢ Base is charged using a Micro-USB to USB Cable with Wall Plug or USB port (supplied separately). See "MydCombiâ„¢ Base Charging and Electrical Information" .
Understanding the Mist and Battery Lights
The Mist Light and the Battery Light show the status of the MydCombiâ„¢ dispenser.
What the Mist and Battery Lights Mean If you see… It means… Mist Light SOLID BLUE Ready to dose Mist Light BLINKING BLUE with Battery Light BLINKING RED & BLUE Reset the dispenser If lights continue blinking after dispenser reset, reset again. If lights continue to blink after second reset, change the cartridge.
- See "TROUBLESHOOTING TIPS" (page 10) for dispenser reset instructions.Battery Light BLINKING GREEN Battery is charging Battery Light SOLID GREEN Battery is fully charged Battery Light BLINKING RED Battery is low Battery Light SOLID RED Charge dispenser base at once
Important Reminders and Cleaning Instructions
- Wash hands prior to using MydCombiâ„¢.
- Before each use, the exterior (including the mirror surface) of the dispenser should be cleaned using a 70% isopropyl alcohol (IPA) wipe or a clean dust-free, cotton cloth dampened with 70% IPA solution.
- Wipe the exterior for 3 minutes. While wiping, pay close attention to all cracks, crevices, and any other hard to reach areas. Additional wipes may be used as needed. Allow the exterior to air dry. Only manual, non-immersion cleaning as described should be used for the dispenser. Do not autoclave (steam sterilize) or immerse in cleaning fluids. Always disconnect power supply from source before cleaning.
- If the patient wears soft contact lenses, they should be removed at least 10 minutes before drug administration.
- If the patient uses artificial tears, they should not be administered within 10 minutes of drug administration.
- Each MydCombiâ„¢ cartridge holds approximately 180 sprays.
- Only use the MydCombiâ„¢ cartridge with the MydCombiâ„¢ base. The MydCombiâ„¢ base will not work with any other type of cartridges.
- See " MydCombiâ„¢ Base Charging and Electrical Information" contained with MydCombiâ„¢ for complete instruction on charging and applicable electrical information.
Storing the MydCombiâ„¢ Base and Cartridges
Store MydCombi™ bases and cartridges at room temperature 15°C to 25°C (59°F to 77°F). Protect from light and excessive heat.
- Do not heat or freeze the MydCombiâ„¢ base or cartridge.- Do not expose MydCombiâ„¢ base to fluids.- Do not tamper with or try to open the MydCombiâ„¢ cartridge or base. Doing so could cause damage and result in personal injury.
The MydCombi™ base contains a lithium-ion battery. Damage to the base can cause fire. Do not puncture base or expose to excessive heat (≥ 50°C).
Li-Ion batteries may pose environmental and safety hazards and should be disposed of in accordance with all applicable Federal and State Laws. Check with all governing travel bodies for current requirements before air travel.
Assembling the MydCombiâ„¢ Dispenser
Complete these steps to assemble the MydCombiâ„¢ base and cartridge.
Note: If packaging is opened or damaged, do not use the contents. Instead, open a new base or cartridge, and contact your distributer for a replacement.
1. Assemble
a. Remove base and/or cartridge from packaging.b. Align base and cartridge, then press together until they click.
- Take care to avoid pressing Fill Button when assembling.
2. Charge Charge MydCombiâ„¢ base before first use (see "MydCombi Base Charging and Electrical Information" contained with MydCombiâ„¢ base packaging). Charging may be performed either before or after assembly.Note: Excessive charging may damage battery or decrease battery life. Charging weekly, or when the Battery Light begins blinking red (signaling low battery) is recommended.
a. Push micro-USB cable into Charging Port.b. Connect opposite end of USB cable to wall outlet plug or USB port.
- Battery light BLINKS GREEN while charging.c. Charge until battery light turns SOLID GREEN, then disconnect cable from Charging Port.
3. Prime
a. Hold MydCombiâ„¢ dispenser upright.b. Firmly press Fill Button down until it stops, and Mist Light turns Blue.c. Slowly release Fill Button, while counting to 3.
- If Fill Button does not return to position, press again until it is all the way down.- If Fill Button still does not return to position, get a new cartridge, and re-assemble (Steps 1 - 2 [page 6]).
Â
d. Point Mist Opening away from face.e. Firmly press, then release Mist Button.f. Repeat Steps a – e until mist emerges from opening.
- If mist does not come out after repeating these steps 5 times, get a new cartridge and re-assemble (Steps 1 - 2 [page 6]).4. MydCombiâ„¢ is now ready to use.
Preparing MydCombiâ„¢ for Use Each Day
Important: A test mist must be performed each day before dosing is commenced.
1. Load drug solution
a. Hold MydCombiâ„¢ dispenser upright.b. Firmly press Fill Button down until it stops, and Mist Light turns Blue.c. Slowly release Fill Button, while counting to 3.
- If Fill Button does not return to position, press again until it is all the way down.- If Fill Button still does not return to position, get a new cartridge, and re-assemble (Steps 1 - 2 [page 6]).
2. Do a test mist
a. Holding MydCombiâ„¢ dispenser upright, point Mist Opening away from face.b. Firmly press and release Mist Button.3. MydCombiâ„¢ is ready to use.
Administering MydCombiâ„¢
Important: Keep MydCombiâ„¢ dispenser upright during use to maintain dose volume.
1. Load drug solution
a. Hold MydCombiâ„¢ dispenser upright and firmly press Fill Button down until it stops, and Mist Light turns Blue.b. Slowly release Fill Button, while counting to 3.
2. Align MydCombiâ„¢ with patient's eyeIf patient is having trouble centering their eye on the blue light, ask that they look up, then look at the BLUE Mirror.
a. Hold MydCombiâ„¢ dispenser with thumb over Mist Button, wrapping other fingers around base.b. Bring MydCombiâ„¢ dispenser to patient's eye with Mirror facing the eye.
- The dispenser should be as close as patient's nose.- To prevent blinking, use your other hand to gently pull lower eyelid down or ask patient to pull her/his lid down.c. Aim Mist Opening toward the center of eye.d. Confirm Alignment Marks (on the Fill Button and the cartridge side) align with the center of eye.
- Ask patient to confirm when their eye is centered on the BLUE Mirror.
3. Press Mist Button
a. Firmly press and release Mist Button.
- The drug solution should gently wet the eye. Repeat Steps 1-3 if needed.Troubleshooting Tips
- If no mist comes out when Mist Button is pressed, confirm Fill Button has been pressed down completely, and has returned to the "up" position.
- If solution is not administered within 1 minute after loading, it will be automatically discharged - the MIST Light will blink blue while the Battery Light blinks red and blue. The MydCombiâ„¢ dispenser must be reset using the steps below.
To reset dispenser:
- Press and release Mist Button.- Press and release Fill Button.- Press and release Mist Button again.- Reload solution (Step 1 [page 9]).
To report suspected adverse reactions please contact Eyenovia, Inc at 1-833-393-6684 (Option 1) or FDA at 1-800-FDA-1088 or http://www.fda.gov/medwatch.
Replacing the MydCombiâ„¢ Cartridge
1. Remove cartridge
a. Hold MydCombiâ„¢ base in one hand. With other hand, press and squeeze Release Tabs on each side of cartridge.b. Pull cartridge and base apart.c. Place used cartridge in original tray and box for disposal or recycling.
Symbols Used in Labels on the MydCombiâ„¢ Cartridge, Base and Packaging
SYMBOL DEFINITION SYMBOL DEFINITION CAUTION, CONSULT ACCOMPANYING DOCUMENTS USE BY (YYYY-MM: YEAR-MONTH) SEE INSTRUCTIONS FOR USE STERILIZED USING ETHYLENE OXIDE CATALOG NUMBER NON-STERILE BATCH CODE DO NOT RESTERILIZE QUANTITY LITHIUM-ION BATTERY - TO BE APPROPRIATELY RECYCLED DATE OF MANUFACTURE (YYYY-MM : YEAR-MONTH) KEEP DRY MANUFACTURER GHS LITHIUM-ION DISPOSAL DO NOT USE IF THE PACKAGING HAS BEEN OPENED OR DAMAGED ELECTRONIC EQUIPMENT. DO NOT THROW IN TRASH. WARNING: ELECTRICITY BY PRESCRIPTION ONLY PROTECTED AGAINST VERTICALLY FALLING WATER DROPS UP TO 15-DEGREE ANGLE TYPE BF PART COMPLYING WITH IEC 60601-1
Manufactured By: Eyenovia295 Madison Ave., Suite 2400New York, NY 10017
© 2022 Eyenovia, Inc. All rights reserved.
Mydcombi Base Charging And Electrical Information
Table of Contents 1. Charging the Mydcombiâ„¢ Base 3 2. Specifications for Mydcombi Base and Charger 4 3. EMC 5 4. Disposal 7 5. Notes on Safety 7 6. Reporting to Manufacturer and Authorities 7 7. Symbols Used in Labels on Mydcombiâ„¢ Base and Packaging 8
1. Charging the Mydcombiâ„¢ Base
NOTE: Do not use base if packaging is opened or damaged. Get a new package by contacting your Eyenovia sales representative or calling 1-833-393-6684 (choose Option 1).
Type of Charger: Micro-USB to USB Cable with Wall Plug or USB port (see section 2 for specifications) Charge Mydcombiâ„¢ Base Before First Use Charging may be performed either before or after assembly with Mydcombiâ„¢ cartridge.Refer to "Instructions for Use - Mydcombiâ„¢ Ophthalmic Spray" for information on cartridge/base assembly and drug administration.Perform the following steps to charge base: Note: Excessive charging may damage battery or decrease battery life. Charging weekly, or when the LED light begins blinking red (signaling low battery), is recommended.
- Push micro-USB cable into charging port.
- Connect opposite end of USB cable to wall outlet plug or USB port.
- Battery light BLINKS GREEN while charging.- Charge until battery light turns SOLID GREEN, then disconnect cable from base.
Battery Indicators on Mydcombi™ Base If Battery Light is… It means… BLINKING GREEN Battery is charging SOLID GREEN Battery is fully charged BLINKING RED Battery is low SOLID RED Charge base at once
2. Specifications for Mydcombi Base and Charger
Base Specifications Parameter Specifications Operating power 4.1VDC Power source Internally powered, Lithium-Ion Battery Instrument make / model Eyenovia / Mydcombi™ Base Dimensions 50 length, 120mm height, 40mm width (When assembled with cartridge) Weight (system) < 100g (When assembled with cartridge) Allowed operating temperature range 15°C to 25°C (59°F to 77°F) Allowed shipping and storage temperature range 15°C to 25°C (59°F to 77°F) at relative humidity of 15% to 90% RH, non-condensing Allowed operation, storage, and shipping humidity range 15°C to 25°C (59°F to 77°F) at relative humidity of 15% to 90% RH, non-condensing Allowed operation, storage, and shipping atmospheric pressure 700hPa to 1060hPa Electrical shock protection - Classification / Degree Internally powered Class I Battery life 2-4 weeks, if used as indicated. Use Life Do not use base longer than 12 months from date of first use, or after Use By Date Software version Software version number can be obtained by calling the manufacturer.
Charger Specifications (Micro-USB to USB Cable with Wall Plug or USB port) Parameter Specifications Type Switching Power Supply Input 100-240V~, 50/60 Hz 200mA Output 5V, 1A USB Cable Minimum Requirements 5V, 1A USB cable must be UL Listed. Must meet US Standard Level VI energy efficiency. Must meet DOE & CEC regulatory requirements.Examples of acceptable cables include those with UL number E178074 or Homespot Model S005AYU0500100.
3. EMC
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in professional medical equipment. This equipment generates, uses, and radiates radio frequency energy and, if not prepared and used in accordance with instructions, may cause harmful interference to radio communications. There is no guarantee, however, that interference will not occur in a particular setting. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off/on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the device and receiver
- Connect the device into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
Note: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the device.
Guidance and Manufacturer's Declaration
This device is intended for use in the electromagnetic environment specified below. The device user should assure use in such an environment.
Electromagnetic emissions Emissions Test Compliance RF emissions CISPR 11 Group 1 RF emissions CISPR 11 Class B Harmonic Emissions IEC 61000-3-2 Class B Voltage Fluctuations/Flicker emissions IEC 61000-3-3 Complies Electromagnetic immunity Phenomena of a continuous nature Shall operate as intended.Shall be no degradation of performance.Shall be no loss of function. Phenomena of transient nature Functions shall be self-recoverable.Shall operate as intended after recovering.Shall be no degradation of performance, Power interruption exceeding a certain time Functions shall be recoverable by the operator.Shall operate as intended after recovering.Shall be no degradation of performance. Immunity Test IEC 60601 Test Level Compliance Level Electrostatic fast transient/burst IEC 61000-4-4 (Charging Only) ±2 kV for power supply lines ±2 kV for power supply lines Surge IEC 61000-4-5 EN/IEC 61000-4-3 L-N (Charging Only) ±1 kV differential mode ±1 kV differential mode EN/IEC 61000-4-3 (Charging Only) Radiated Immunity3 V/m, 80 – 2700 MHz80% AM at 1 kHz & Proximity Fields from RFWireless Communications Equipment Radiated Immunity3 V/m, 80 – 2700 MHz80% AM at 1 kHz & Proximity Fields from RFWireless Communications Equipment Voltage dips, short interruptions, and voltage variations on power supply input lines IEC 61000-4-11 Voltage Dips 30% reduction, 25/30 periodsAt 0° Voltage Dips 30% reduction, 25/30 periodsAt 0° Voltage Dips > 95% reduction, 0.5 periodAt 0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315° Voltage Dips > 95% reduction, 0.5 periodAt 0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315° Voltage Dips > 95 reduction, 1 periodAt 0° Voltage Dips > 95 reduction, 1 periodAt 0° Voltage Interruptions > 95% reduction, 250/300 periods Voltage Interruptions > 95% reduction, 250/300 periods Conducted RF EN/IEC 61000-4-6 Continuous Conducted RF,80% AM (1 kHz)3 Vrms, 0.15-80 MHz6 Vrms in ISM and amateur radio Bands within 150kHz – 80MHz Continuous Conducted RF,80% AM (1 kHz)3 Vrms, 0.15-80 MHz6 Vrms in ISM and amateur radio Bands within 150kHz – 80MHz Magnetic field IEC 61000-4-8 Power Frequency Magnetic Field 30Arms/m at 50/60Hz Power Frequency Magnetic Field 30Arms/m at 50/60Hz
Immunity to RF Wireless Communications Equipment Test Frequency (MHz) Band For some services, only uplink frequencies are included. (MHz)Service Modulation The carrier shall be modulated using a 50% duty cycle square wave signal. Max. Power (W) Distance (m) Immunity test level (V/m) 385 380 –390 TETRA 400 Pulse 18 Hz 1.8 0.3 27 450 430 – 470 GMRS 460, FRS 460 FM As an alternative to FM modulation, 50% pulse modulation at 18 Hz may be used because, while it does not represent actual modulation, it would be worst case. ± 5 kHz Deviation 1 kHz sine2 0.3 28 710 704 – 787 LTE Band 13, 17 Pulse 217 Hz 0.2 0.3 9 745 780 810 800 – 960 GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 Pulse 18 Hz 2 0.3 28 870 930 1720 1 700 – 1 990 GSM 1800; CDMA 1900; GSM 1900; DECT; LTE Band 1, 3, 4, 25; UMTS Pulse 217 Hz 2 0.3 28 1845 1970 2450 2 400 – 2 570 Bluetooth, WLAN, 802.11 b/g/n, RFID 2450, LTE Band 7 Pulse 217 Hz 2 0.3 28 5240 5 100 – 5 800 WLAN 802.11 a/n Pulse 217 Hz 0.2 0.3 9 5500 5785
Recommended separation distances between portable and mobile RF communications equipment and the device, except for the distances indicated in the following table "Immunity to RF Wireless Communications Equipment". The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. Users can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter (W) Separation distance according to frequency of transmitter (m) 150 kHz to 80 MHz d = 1.2√P 80 MHz to 800 MHz d = 1.2√P 800 MHz to 2.7 GHz d = 2.3√P 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 For transmitters rated at a maximum output power not uled above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.
4. Disposal
Contains Lithium-Ion Battery Lithium-Ion batteries may pose environmental and safety hazards and should be disposed of in accordance with all applicable Federal and State laws. Electronic Equipment Base should be properly disposed of in accordance with all applicable State and Federal laws.
5. Notes on Safety
Warnings and Recommendations
Contains Lithium-Ion Battery Damage can cause fire. Do not puncture. Do not expose to excessive heat (≥ 50°C). Do not use after expiration date Expiration date is published on base label. Discontinue use if expiration date has passed. Inspect for device damage Do not use if package has been opened or damaged or if there is evidence of base damage. Doing so could result in injury. Tampering with parts in the Mydcombi™ Base Do not tamper with or attempt to open the base. Doing so could cause damage and result in personal injury. Risk of usage Failure to use base in accordance with instructions could affect dose dispensation. Keep base in upright position during use. If base has been idling for an extended period, dispense a waste spray. Optejet will not dispense drug while the base is actively charging. Risk due to insufficient user training Use base only with Mydcombi™ Cartridge. Refer to "Instructions for Use - Mydcombi™ Ophthalmic Spray". Risk due to battery leakage Do not use base if there is any sign of battery leakage. Keep dry Do not expose base to fluids; keep dry. Transportation and Storage Do not store or transport base with sharp or metallic objects. Risk of electrical leakage Non-hazardous voltage is present during normal use. Do not use with other equipment Do not use with non-certified USB charger Recharge base using a micro-USB cable (not included). Use of a charger other than that specified in Section 2 - Specifications could result in increased electromagnetic emissions or decreased electromagnetic immunity of the base, resulting in improper operation. CAUTION – For professional use Federal law restricts this device to sale by or on the order of a physician (21 CFR§801.109(b)(1)). CAUTION – Radiation emission This device emits electromagnetic radiation.
6. Reporting to Manufacturer and Authorities
If a serious incident occurs in connection with this device that affects the user or another person, please report incident to Eyenovia by calling 1-833-393-6684 (choose Option 1) or FDA at 1-800-FDA-1088 or http://www.fda.gov/medwatch.
7. Symbols Used in Labels on Mydcombiâ„¢ Base and Packaging
SYMBOL DEFINITION SYMBOL DEFINITION CAUTION, CONSULT ACCOMPANYING DOCUMENTS USE BY (YYYY-MM: YEAR-MONTH) SEE INSTRUCTIONS FOR USE ELECTRONIC EQUIPMENT. DO NOT THROW IN TRASH. CATALOG NUMBER NON-STERILE BATCH CODE KEEP DRY QUANTITY LITHIUM-ION BATTERY - TO BE APPROPRIATELY RECYCLED DATE OF MANUFACTURE (YYYY-MM : YEAR-MONTH) MANUFACTURER WARNING: ELECTRICITY CAUTION: FEDERAL LAW RESTRICTS THIS PRODUCT PROTECTED AGAINST VERTICALLY FALLING WATER DROPS UP TO 15-DEGREE ANGLE TYPE BF PART COMPLYING WITH IEC 60601-1
MANUFACTURED BY Contact / Return Goods Policy Eyenovia, Inc.8748 Technology Way, Reno, NV 89521© 2022 Eyenovia, Inc. All rights reserved.www.eyenovia.com Contact your sales representative or Eyenovia for product returns. Call 1-833-EYENOVIA (393-6684)admin@eyenovia.com
Principal Display Panel - Mydcombi Base Unit Label
MydCombiâ„¢ BaseNon-Sterile
REF FG-16427 LOT F-#####YYYY-MM-DD
Li-ion
15°C59°F
25°C77°F
IPX2
Eyenovia, Inc.295 Madison Ave, Ste 2400New York, NY 10017
(01) 008600099909700(10) F-123465(17) 250405
Rx ONLYLS-17076-E
Principal Display Panel - Mydcombi Base Unit Carton
eyenovia
Rx ONLYLS-17075-D
REF FG-16427 MydCombiâ„¢ BaseLOT F-#####QTY 1
USE BY YYYY-MM-DD
YYYY-MM-DD
Eyenovia, Inc.295 Madison Ave, Ste 2400New York, NY 10017
Li-ion
NONSTERILE
IPX2
15°C59°F
25°C77°F
Principal Display Panel - Mydcombi Base Single Carton Label
LS-17078-D
MydCombiâ„¢
Tropicamide and PhenylephrineHCl Ophthalmic Spray 1% / 2.5 %
For Topical Ophthalmic Use
Exp: YYYY-MMLOT ############
Manufactured for:Eyenovia, Inc.295 Madison Ave, Ste 2400New York, NY 10017
NDC 81046-0111-1
Sterile 1.9mL Rx Only
Principal Display Panel - Mydcombi Base Single Carton
MydCombiâ„¢
Sterile
Rx Only
Tropicamide and Phenylephrine HCl Ophthalmic Spray 1% / 2.5 %
MydCombi CartridgeNDC 81046-0111-1
LOT ########## QTY 1
YYYY-MM
Eyenovia, Inc.295 Madison Ave, Ste 2400New York, NY 10017
STORAGEStore at room temperature 15°C to 25°C (59°F to 77°F).
Principal Display Panel - Mydcombi Cartridge And Base Carton
Rx ONLYLS-17081-D
MydCombiâ„¢
NDC: 81046-0111-2
Tropicamide and Phenylephrine HCl Ophthalmic Spray 1% / 2.5 %
MydCombi Cartridge
STORAGEStore at room temperature 15°C to 25°C (59°F to 77°F).QTY 1
BASE UNIT
REF FG-16427 MydCombi BaseQTY 1
STORAGEStore at room temperature 15°C to 25°C (59°F to 77°F).
Eyenovia, Inc.295 Madison Avenue, Suite 2400New York, NY 10017
Li-ion
NONSTERILE
IPX2
15°C59°F
25°C77°F
Principal Display Panel - Mydcombi Cartridge And Base 5 Pack Box
MydCombiâ„¢
QTY 5
SterileRx Only
Tropicamide and Phenylephrine HCl Ophthalmic Spray 1% / 2.5 %
Eyenovia, Inc.295 Madison Avenue, Suite 2400New York, NY 10017
MydCombi CartridgeNDC 81046-0111-5
STORAGEStore at room temperature 15°C to 25°C (59°F to 77°F).
NDC: 81046-0111-05SN: ABC098DEF765GHI432JKEXP: YYYY-MMLot: MCL123
LOT ##########
YYYY-MM
LS-17079-E
DISCLAIMER:
"This tool does not provide medical advice, and is for informational and educational purposes only, and is not a substitute for professional medical advice, treatment or diagnosis. Call your doctor to receive medical advice. If you think you may have a medical emergency, please dial 911."
"Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service."
"This product uses publicly available data from the U.S. National Library of Medicine (NLM), National Institutes of Health, Department of Health and Human Services; NLM is not responsible for the product and does not endorse or recommend this or any other product."
PillSync may earn a commission via links on our site