Oxygen Dailymed
Generic: oxygen is used for the treatment of Carbon Monoxide Poisoning Hypoxia, Brain Cluster Headache Decompression Sickness Embolism, Air Gangrene Lung Diseases, Obstructive Pneumonia Pulmonary Edema Pulmonary Fibrosis Respiratory Insufficiency Retinopathy of Prematurity Wound Infection
Go PRO for all pill images
Package Label.principal Display Panel
OXYGEN, COMPRESSED USP UN1072AWI SUPPLY 230 Valley Street Hot Springs, AR 71901 501-321-9922OXYGEN 2WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx only. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction. DANGER: MAY CAUSE OR INTENCIFY FIRE; OXYDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. In case of fire; Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52 C (125 F). Read and follow the Safety Data Sheet (SDS) before use.CAS: 7782-44-7 DO NOT REMOVE THIS PRODUCT LABEL
Package Label.principal Display Panel
AWI SUPPLY OXYGEN PRODUCED BY AIR-LIQUEFACTION PROCESS MEETS USP REQUIREMENTS
FACILITY___ UNIT NO.___ TESTER NO.___ QUANTITY___CU.FT.
LOT NO.___ PURITY___ IDENTITY___ ___ODOR WITNESS___
DATE___ OPERATOR___
ARKANSES WELDING AND INDUSTRIAL SUPPLY, INC. CERTIFIES THE OXYGEN PRODUCT DELIVERED MEETS AND EXCEEEDS PURITY SPECIFICATIONS FOR USP PRODUCT AS DEFINED BY THE FOOD AND DRUG ADMINISTRATION.
THIS TAG MUST BE REMOVED ONLY BY EMPLOYEE RESPONSIBLE FOR REFILLING
Package Label.principal Display Panel
OXYGEN, COMPRESSED USP
UN1072
WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx only. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction. DANGER: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52 C (125 F). Read and follow the Safety Data Sheet (SDS) before use. CAS: 7782-44-7 DO NOT REMOVE THIS PRODUCT LABEL.
AWI SUPPLY
230 Valley St.
Hot Springs, AR 71901
888-999-9353
DISCLAIMER:
"This tool does not provide medical advice, and is for informational and educational purposes only, and is not a substitute for professional medical advice, treatment or diagnosis. Call your doctor to receive medical advice. If you think you may have a medical emergency, please dial 911."
"Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service."
"This product uses publicly available data from the U.S. National Library of Medicine (NLM), National Institutes of Health, Department of Health and Human Services; NLM is not responsible for the product and does not endorse or recommend this or any other product."
PillSync may earn a commission via links on our site