(c) 2024 PillSync.com

Generic: fibrinogen human, human thrombin is used for the treatment of Hemorrhage Afibrinogenemia


Go PRO for all pill images

1 Indications And Usage


Hemostasis: TISSEEL is a fibrin sealant indicated for use as an adjunct to hemostasis in adult and pediatric patients (>1 month of age) undergoing surgery when control of bleeding by conventional surgical techniques (such as suture, ligature, and cautery) is ineffective or impractical. TISSEEL is effective in heparinized patients.

Sealing: TISSEEL is a fibrin sealant indicated as an adjunct to standard surgical techniques (such as suture and ligature) to prevent leakage from colonic anastomoses following the reversal of temporary colostomies.


Hemostasis: TISSEEL is a fibrin sealant indicated for use as an adjunct to hemostasis in adult and pediatric patients (>1 month of age) undergoing surgery when control of bleeding by conventional surgical techniques (such as suture, ligature, and cautery) is ineffective or impractical. TISSEEL is effective in heparinized patients. (1)

Sealing: TISSEEL is a fibrin sealant indicated as an adjunct to standard surgical techniques (such as suture and ligature) to prevent leakage from colonic anastomoses following the reversal of temporary colostomies. (1)

2 Dosage And Administration


FOR TOPICAL USE ONLY – DO NOT INJECT

Vials and pre-filled syringes are for single-patient use only. Discard any unused product.


For Topical Use Only. Do Not Inject (2)
  • •Apply TISSEEL as a thin layer by dripping or spraying using cannula or spray set. (2.3, 5.2)
  • •Ensure that the amount of TISSEEL to be applied is sufficient to entirely cover the intended application area. (2.3)

2.1 Preparation of TISSEEL Kit (Freeze-Dried)


Do not expose to temperature above 37ºCDo not microwaveDo not refrigerate or freeze after reconstitution

Do not use iodine or heavy metal containing preparations such as betadine for disinfection of vial stoppers. Allow alcohol-based disinfectants to evaporate before puncturing stopper.

Use separate syringes and transfer devices for reconstituting Sealer Protein and Thrombin solutions and for application to prevent clotting.

The product must be used within 4 hours after reconstitution.

Freeze-dried Sealer Protein Concentrate and Thrombin are reconstituted in Fibrinolysis Inhibitor Solution and Calcium Chloride Solution, respectively. The Sealer Protein Solution and Thrombin Solution are then combined using the DUPLOJECT Preparation and Application System, or an equivalent delivery device cleared by FDA for use with TISSEEL, to form the Fibrin Sealant.

Pre-warming TISSEEL Kit with FIBRINOTHERM device See FIBRINOTHERM device manual for complete operating instructions. If a FIBRINOTHERM device is not available, contact Baxter (1-800-229-0001) for assistance.
  • 1.Place all four vials from the TISSEEL Kit into the pre-warmed wells of the FIBRINOTHERM device, using the appropriately sized adapter ring(s), and allow the vials to warm for up to 5 minutes (room temperature product will take less time).

Preparation of Sealer Protein Solution with FIBRINOTHERM device
  • 1.Remove the caps from the Sealer Protein Concentrate and the Fibrinolysis Inhibitor Solution vials.
  • 2.Transfer the Aprotinin (Fibrinolysis Inhibitor Solution) into the vial containing the freeze-dried Sealer Protein Concentrate using the sterile reconstitution components (see directions provided with the device system for specific reconstitution instructions). Gently swirl the vial to ensure that the product is completely soaked.
  • 3.Place the vial into the largest opening of the FIBRINOTHERM device with the appropriate adapter ring. Switch on the stirrer and allow the vial contents to stir until all Sealer Protein Concentrate is dissolved. Reconstitution is complete when no undissolved particles are visible.

Notes:
  • -If the Sealer Protein Concentrate has not fully dissolved within 20 minutes discard the vial and prepare a fresh kit.
  • -Keep the Sealer Protein Solution at 37°C without stirring. Stir shortly before drawing up the solution to ensure homogeneity.

Preparation of Thrombin Solution with FIBRINOTHERM device

To reconstitute the Thrombin (Human) with the Calcium Chloride Solution; follow steps 1-3 under Preparation of Sealer Protein with FIBRINOTHERM device utilizing the Thrombin and Calcium Chloride vials.

Transferring to the Sterile Field

For transfer of the Sealer Protein and Thrombin Solutions to the sterile field, the circulating nurse should disinfect the tops of the vials with a germicidal solution and allow to dry. The scrub nurse should withdraw the sterile solutions while the circulating nurse holds the non-sterile vials. Slowly withdraw the solution, by firm constant aspiration, to reduce the risk of large air bubbles.

2.2 Preparation of TISSEEL Pre-Filled Syringe (Frozen)


Do not expose to temperature above 37ËšC Do not microwave.Do not refrigerate or re-freeze after thawing.Do not use TISSEEL (frozen) until it is completely thawed and warmed (liquid consistency) to 33-37oC. Do not remove the protective syringe cap until use.

AST Syringe – The plunger rod must be inserted into the syringe barrel (see ). PRIMA Syringe – The plunger is already assembled with the syringe barrel (see Figure 2).

Sterile Water Bath (Quick Thawing): Transfer inner pouch to the sterile field, remove pre-filled syringe from inner pouch and place directly into sterile water bath ensuring the syringe is completely immersed in the water. Maintain the product at 33-37°C until use. Once the package is opened or the product is warmed to 33-37°C, it must be used within 4 hours.

Non-Sterile Water Bath: Maintain the pre-filled syringe in pouches and place into a water bath outside the sterile field ensuring the pouches remain submerged. Remove from the water bath after thawing and warming, dry the external pouch and transfer inner pouch with pre-filled syringe onto the sterile field. Maintain the product at 33-37°C until use. Once the package is opened or the product is warmed to 33-37°C, it must be used within 4 hours.

Incubator: Maintain the pre-filled syringe in pouches and place into an incubator. Remove from the incubator after thawing and warming. Transfer inner pouch with pre-filled syringe onto the sterile field. Maintain the product at 33-37°C until use. Once the package is opened or the product is warmed to 33-37°C, it must be used within 4 hours.
Table 1: Approximate Water Bath or Incubator Thawing and Warming Times

Pack Size

Sterile Water Bath

(Pouches Removed)

33 - 37°C

Non-Sterile Water Bath

(In Pouches)

33 - 37°C

Incubator

(In Pouches)

33 - 37°C

PRIMA Syringe

AST Syringe

PRIMA Syringe

AST Syringe

PRIMA Syringe

AST Syringe

2 mL

5 minutes

5 minutes

15 minutes

30 minutes

40 minutes

40 minutes

4 mL

5 minutes

5 minutes

20 minutes

40 minutes

50 minutes

85 minutes

10 mL

10 minutes

12 minutes

35 minutes

80 minutes

90 minutes

105 minutes

Room Temperature Thawing: Unopened pouches can be stored for up to 48 hours at room temperature (15-25°C). Before use, warm the product to 33-37°C and apply immediately. The total thawing and warming time cannot exceed 48 hours.
Table 2: Approximate Room Temperature Thawing Times

Pack Size

Room Temperature

(In Pouches)

15 – 25oC

PRIMA Syringe

AST Syringe

2 mL

80 minutes

60 minutes

4 mL

90 minutes

110 minutes

10 mL

160 minutes

160 minutes
Table 3: Approximate Water Bath or Incubator Warming Times for Thawed Product

Pack Size

Sterile Water Bath

(Pouches Removed)

33 – 37°C

Non-Sterile Water Bath

(In Pouches)

33 – 37°C

Incubator

(In Pouches)

33 – 37°C

PRIMA Syringe

AST Syringe

PRIMA Syringe

AST Syringe

PRIMA Syringe

AST Syringe

2 mL

2 minutes

2 minutes

5 minutes

16 minutes

16 minutes

20 minutes

4 mL

2 minutes

2 minutes

8 minutes

21 minutes

21 minutes

43 minutes

10 mL

4 minutes

6 minutes

12 minutes

43 minutes

35 minutes

52 minutes

2.3 Method of Application


TISSEEL Kit (Freeze-Dried)

Apply TISSEEL using the DUPLOJECT Fibrin Sealant Preparation and Application System or an equivalent delivery system (including open and minimally invasive spray devices) cleared by FDA for use with TISSEEL. Specific instructions for the use of TISSEEL in conjunction with each cleared delivery device are provided with the device.

TISSEEL Pre-filled Syringe Frozen

Apply pre-filled TISSEEL using the joining piece and application cannula accessory devices provided with the product or an equivalent delivery device (including open and minimally invasive spray devices) cleared by the FDA for use with TISSEEL.

DUO Set (AST Syringe) Instructions (see ):
  • 1.Insert plunger into syringe barrel.
  • 2.Remove all air from the double chamber syringe.
  • 3.Firmly connect the two syringe nozzles to the joining piece (Y-connector) and secure it by fastening the tether strap to the syringe.
  • 4.Fit an application cannula to the joining piece. Apply by depressing plunger.

DUPLOJECT COMBI (PRIMA Syringe) Instructions (see )
  • 1.The plunger is attached to the syringe barrel and does not need to be inserted.
  • 2.Remove all air from the double chamber syringe.
  • 3.Firmly connect the two syringe nozzles to the joining piece (Y-connector) and secure it by fastening the tether strap to the syringe.
  • 4.Fit an application cannula to the joining piece. Apply by depressing plunger.
  •  Note: Interruption of TISSEEL application causes clogging in the cannula. Replace the cannula immediately prior to resuming application. If the opening of the joining piece (Y-connector) facing the cannula is clogged, use the spare joining piece provided in the package.
Figure 1 DUO SET - AST Syringe Figure 2: DUPLOJECT COMBI - PRIMA Syringe
TISSEEL must be sprayed only onto application sites that are visible. Dry the site of application as much as possible. The surface area of the wound needs to be dried using standard techniques (e.g. intermittent application of compresses, swabs, use of suction devices). Do not use pressurized air or gas to dry the site.

When applying TISSEEL using a spray device, utilize the recommended gas, pressure and distance from tissue within the ranges recommended by the manufacturer as follows:
Table 4: Recommended Application Equipment, Gas and Parameters

Surgery

Spray set / Applicator tips to use

Pressure regulator to use

Gas

Distance

Spray Pressure

Open surgery

TISSEEL /ARTISS

Spray Set

EASY SPRAY

Pressure Regulator

Medical grade CO2Medical grade CO2 is the preferred gas for application, however compressed Air or Nitrogen are acceptable gasses for administration of TISSEEL in open surgery., Compressed

Air or Nitrogen

10-15 cm

1.5-2.0 bar

(21.8-29.0 psi)

Laparoscopic/ minimally invasive procedures

DUPLOSPRAY MIS Applicator 20 cm

DUPLOSPRAY

MIS Regulator

CO2 Only

Range 2-5 cm

3 cm recommended

1.18-1.50 bar

(17-22 psi)

DUPLOSPRAY MIS Applicator 30 cm

DUPLOSPRAY MIS Applicator 40 cm

360º Flexible

Applicator 40 cm

Replaceable tip

Apply TISSEEL as a thin layer by dripping or spraying using a cannula or spray set approved for use with TISSEEL. To reduce the risk of potentially life-threatening gas embolism, spray TISSEEL using only the appropriate pressurized gas within the pressure range and distance recommended in the device Instructions For Use (see Warnings and Precautions (5.2) ). The treating physician will determine the amount of TISSEEL to be applied based on the surface to be covered. Ensure that the amount applied is sufficient to entirely cover the intended application area. The approximate surface areas covered by each package size of TISSEEL are uled in Table 5:
Table 5: Surface Area Coverage

Required package size of

TISSEEL

Maximum coverage using spray

Maximum coverage using cannula

2 mL4 mL10 mL

100 cm2 200 cm2 500 cm2

8 cm2 16 cm2 40 cm2

Avoid application beyond the intended area. Allow at least 2 minutes after application to achieve sufficient polymerization. If repeat application is needed, dry the site as much as possible before reapplying. Reapply after removing residues from the prior application or before polymerization takes place since TISSEEL may not adhere firmly to a polymerized layer.

In cases where very small volumes (1-2 drops) are required, expel and discard the first several drops from the application cannula immediately before application to ensure administration of adequately mixed TISSEEL.

3 Dosage Forms And Strengths


TISSEEL Kit (Freeze-Dried) is supplied as 2 mL, 4 mL and 10 mL (total volume) pack sizes with and without the DUPLOJECT Fibrin Sealant Preparation and Application System. TISSEEL Pre-Filled Syringe (Frozen) is supplied as 2 mL, 4 mL and 10 mL (total volume) pack sizes with the DUO Set (AST Syringe) or DUPLOJECT COMBI (PRIMA Syringe).


TISSEEL Kit (Freeze-Dried) is supplied as 2 mL, 4 mL and 10 mL (total volume) pack sizes with and without the DUPLOJECT Fibrin Sealant Preparation and Application System. (3)

TISSEEL Pre-filled Syringe (Frozen) is supplied as 2 mL, 4 mL and 10 mL (total volume) pack sizes with DUO Set (AST syringe) or DUPLOJECT COMBI (PRIMA syringe). (3)

4 Contraindications


  • •Do not inject directly into the circulatory system or into highly vascularized tissue. (4.1, 5.3)
  • •Do not use in individuals with a known hypersensitivity to aprotinin. (4.2, 5.1, 6)
  • •Do not use for the treatment of severe or brisk arterial or venous bleeding. (4.3)
  • •Do not spray where the minimum recommended distance from the applicator tip to the target site cannot be assured. (4.4).

4.1 Intravascular Application


Do not inject TISSEEL directly into the circulatory system or into highly vascularized tissue. Intravascular application of TISSEEL can lead to intravascular coagulation, can result in life-threatening thromboembolic events, and can increase the likelihood and severity of acute hypersensitivity reactions in susceptible patients (see Warnings and Precautions (5.3 ) and Adverse Reactions (6.2) ).

4.2 Aprotinin Hypersensitivity


Do not use TISSEEL in individuals with a known hypersensitivity to aprotinin (see Warnings and Precautions (5.1) and Adverse Reactions (6) ).

4.3 Severe or Brisk Bleeding


Do not use TISSEEL for treatment of severe or brisk arterial or venous bleeding. In these situations, TISSEEL will be washed away in the flow of blood before hemostasis can be attained.


Do not spray TISSEEL where the minimum recommended distance from the applicator tip to the target site cannot be assured.

5 Warnings And Precautions


  • •TISSEEL contains aprotinin, a protein known to be associated with anaphylactic reactions. (4.2, 5.1, 6)
  • •To reduce the risk of potential life-threatening gas embolism, spray using only the appropriate pressurized gas at the recommended pressure and distance. For Open Surgical procedures, use the EASYSPRAY device connected to CO2, Medical Air or Nitrogen. For Minimally Invasive Surgery procedures use the DUPLOSPRAY MIS device connected only to CO2.(5.2)
  • •TISSEEL is denatured when exposed to solutions containing alcohol, iodine or heavy metals. (5.2)
  • •Apply only as a thin layer as excess clot thickness can negatively interfere with wound healing. (2, 5.2)
  • •When using TISSEEL in surgery do not inject intravascularly. (4.1, 5.3, 6.2).
  • •Safety has not been evaluated in neurosurgical procedures. (5.4)
  • •TISSEEL is made from pooled human plasma which can contain infectious agents. (5.5)

5.1 Hypersensitivity Reactions


Hypersensitivity reactions including allergic/and anaphylactoid reactions can occur with the use of TISSEEL. Cases have been reported in post marketing experience with Baxter’s fibrin sealant (see Adverse Reactions (6.2) ). In specific cases, these reactions have progressed to severe anaphylaxis. Such reactions may especially be seen if TISSEEL is applied repeatedly over time or in the same setting, or if systemic aprotinin has been administered previously. Even if the first treatment was well tolerated, this may not exclude the occurrence of an allergic reaction after a subsequent administration of TISSEEL or systemic aprotinin. Observed symptoms of allergic anaphylactic reactions to TISSEEL have included: bradycardia, tachycardia, hypotension, flushing, bronchospasm, wheezing, dyspnea, nausea, urticaria, angioedema, pruritus, erythema and paresthesia. Such reactions can also occur in patients receiving TISSEEL for the first time.

Aprotinin is included in TISSEEL for its antifibrinolytic properties. Aprotinin, a protein, is known to be associated with anaphylactic reactions. Even in the case of strict local application of aprotinin, there is a risk of anaphylactic reactions to aprotinin, particularly in the case of previous exposure (see Contraindications (4.2)). TISSEEL does not contain any substances of bovine origin.

Discontinue administration of TISSEEL in the event of hypersensitivity reactions. Mild reactions can be managed with antihistamines. Severe hypotensive reactions require immediate intervention using current principles of shock therapy. Remove remaining product from the application site.

5.2 Application Precautions


Any application of pressurized air or gas is associated with a potential risk of air or gas embolism, tissue rupture, or gas entrapment with compression, which may be life a threatening or fatal.

Life threatening/fatal air or gas embolism has occurred when Fibrin Sealants were administered using pressurized gas with open regulator spray devices. This can occur if a spray device is used at higher than recommended pressures and in closer than recommended proximity to the tissue surface. The solubility of compressed CO2 is greater than either compressed N2 or Air thereby reducing the potential effect of embolization.

Regardless of the type of gas used, to reduce the incidence of embolization, spray TISSEEL using only the recommended regulator, set within the recommended pressure range, with the appropriate applicator positioned at the recommended distance in Table 4.

Monitor changes in blood pressure, pulse, oxygen saturation and endtidal CO2 due to the possibility of air or gas embolism.

Use only spray catheters or applicators approved for use with TISSEEL.

TISSEEL must not be sprayed in enclosed body areas using the EASYSPRAY device and must be sprayed onto only visible application sites.

For Open Surgical procedures, use the EASYSPRAY Pressure Regulator connected to medical grade CO2, compressed Air or a Nitrogen compressed gas source along with the TISSEEL/ARTISS spray set, (see Method of Application (2.3) ).

For Minimally Invasive Surgery procedures in enclosed body areas use of the DUPLOSPRAY MIS device connected only to compressed CO2, along with DUPLOSPRAY applicator is recommended. The DUPLOSPRAY MIS device is specifically designed to prevent over pressurization of the body cavity through a dedicated ventline to reduce the risk of gas embolization, (see Method of Application (2.3) ).

The sealer protein and thrombin solutions are denatured by alcohol, iodine or heavy metal ions. If any of these substances have been used to clean the wound area, the area must be thoroughly rinsed before the application of TISSEEL.

Apply TISSEEL as a thin layer as excess clot thickness can negatively interfere with wound healing.

5.3 Use in Surgery


When using TISSEEL in surgery, do not inject intravascularly (see Contraindications (4.1) and Adverse Reactions (6.2) ).

5.4 Use in Neurosurgical Procedures


The safety and effectiveness of TISSEEL used alone or in combination with biocompatible carriers in neurosurgical procedures or other surgeries involving confined spaces have not been evaluated, and its use in this setting is not approved by FDA (see Adverse Reactions (6.2 ) and Drug Interactions (7) ).

5.5 Infection Risk from Human Plasma


TISSEEL is made from human plasma. Because this product is made from human blood, it may carry a risk of transmitting infectious agents, e.g., viruses, the variant Creutzfeldt-Jakob disease (vCJD) agent and, theoretically the Creutzfeldt-Jakob disease (CJD) agent.

All infections thought by a physician possibly to have been transmitted by this product should be reported by the physician or other healthcare provider to Baxter Healthcare Corporation at 1-888-229-0001.

6 Adverse Reactions



Hypersensitivity or allergic/anaphylactoid reactions have occurred. (6)

To report SUSPECTED ADVERSE REACTIONS, contact Baxter Healthcare Corporation at 1-888-229-0001 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.

6.1 Clinical Trials Experience


Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice.

Increased D-Dimer levels have been observed during a clinical study in cardiovascular surgery (see Clinical Studies (14) ), but did not exceed values reported in the literature occurring after this type of surgery. Postoperatively increased D-Dimers can result at least partly from the degradation of Fibrin Sealant.

There were no reports of serious, associated adverse reactions reported above 1% in clinical studies.

6.2 Post-Marketing Experience


Because adverse reactions are reported voluntarily and the population is of uncertain size, it is not always possible to reliably estimate the frequency of these reactions.

The following adverse reactions have been reported in the post-marketing experience.

Immune System Disorders: Hypersensitivity, including anaphylactic reaction and anaphylactic shock. Anaphylactic reactions and anaphylactic shock have included fatal outcomes. Vascular Disorders: Hypotension, flushing, embolism, including cerebral artery embolism, cerebral infarction*, air embolism** Skin and subcutaneous Tissue Disorders: Angioedema, erythema, impaired healing, pruritus, urticaria Cardiac Disorders: Bradycardia, tachycardia Respiratory Disorders: Bronchospasm, dyspnea, wheezing Gastrointestinal Disorders: Nausea Nervous System Disorders: Paresthesia * as a result of intravascular application into the superior petrosal sinus ** As with other fibrin sealants life-threatening/fatal air or gas embolism when using devices with pressurized air or gas occurred; this event appears to be related to an inappropriate use of the spray device (e.g. at higher than recommended pressure and in close proximity to the tissue surface),

Class effect: Manifestations of hypersensitivity or allergic reactions associated with the class of fibrin sealant/hemostatic products include: application site irritation, chest discomfort, chills, headache, lethargy, restlessness and vomiting.

There have been reports of serious adverse events such as paralysis and other compressive complications possibly related to the use of fibrin sealants in combination with resorbable hemostatic agents. There have also been reports of fatalities following the misadministration of topical thrombin (see Warnings and Precautions (5.4) ).

7 Drug Interactions


Oxidized cellulose-containing preparations can reduce the efficacy of TISSEEL and should not be used as carrier materials. No interaction studies have been performed.


Oxidized cellulose-containing preparations can reduce the efficacy of TISSEEL and should not be used as carrier materials. (7)

8 Use In Specific Populations


8.1 Pregnancy


Risk Summary

There are no direct or controlled studies of TISSEEL in pregnant women. No animal reproductive and developmental toxicity studies have been conducted with TISSEEL. It is also not known whether TISSEEL can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. Some viruses, such as parvovirus B19, are particularly difficult to remove or inactivate. Parvovirus B19 most seriously affects pregnant women (fetal infection). In the United States general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2% to 4% and 15% to 20%, respectively.

8.2 Lactation


Risk Summary

There is no information regarding the presence of TISSEEL in human milk, the effects on the breastfed infant, or the effects on milk production.  The developmental and health benefits of breastfeeding should be considered along with the mother’s clinical need for TISSEEL and any potential adverse effects on the breastfed infant from TISSEEL or from underlying maternal condition.

8.4 Pediatric Use


Limited clinical study data are available with regard to the use of TISSEEL in children. Of 365 patients undergoing repeated cardiac surgery or emergency resternotomy in a clinical trial of TISSEEL, 27 pediatric patients aged 16 years or younger were treated with TISSEEL. Of these, 2 patients were less than 6 months, 2 patients were between the ages of 6 months and 2 years, 15 patients were between 3-11 years of age, and 8 patients were between 12-16 years of age. There were no differences in safety observed between these subjects and the overall population. (see Clinical Studies (14) ).

8.5 Geriatric Use


Clinical studies included 218 patients aged 65 years of age or older treated with TISSEEL (159 undergoing cardiac surgery and 59 undergoing vascular surgery) (see Clinical Studies (14) ). No overall differences in safety or effectiveness were observed between these subjects and younger subjects, and other reported clinical experience has not identified differences in responses between the elderly and younger patients, but greater sensitivity of some older individuals cannot be ruled out.

11 Description


TISSEEL [Fibrin Sealant] is a two-component fibrin sealant made from pooled human plasma. When combined, the two components, Sealer Protein and Thrombin mimic the final stage of the blood coagulation cascade.

Sealer Protein (Human) Sealer Protein (Human) is a sterile, non-pyrogenic, vapor heated and solvent/detergent treated preparation made from pooled human plasma. Sealer Protein (Human) is provided either as a freeze-dried powder for reconstitution with Aprotinin or as a finished frozen solution pre-filled into one side of a dual-chambered syringe. The active ingredient in Sealer Protein (Human) is fibrinogen. Sealer Protein (Human) solution contains fibrinolysis inhibitor, synthetic Aprotinin, that delays fibrinolysis. Aprotinin (Synthetic) is manufactured by solid phase synthesis from materials completely of non-human/non-animal origin.

Thrombin (Human) Thrombin (Human) is a sterile, non-pyrogenic, vapor heated and solvent/detergent treated preparation made from pooled human plasma. Thrombin (Human) is also provided either as a freeze-dried powder for reconstitution with Calcium Chloride Solution or as a finished frozen solution pre-filled into one side of a dual-chambered syringe.
  •  The reconstituted solution or pre-filled syringe contains: Sealer Protein Solution
  •  Total protein: 96 – 125 mg/mL Fibrinogen: 67 – 106 mg/mLAprotinin (Synthetic): 2250 – 3750 KIU/mLOther ingredients include: human albumin, tri-sodium citrate, histidine, niacinamide, polysorbate 80 and water for injection.
  •  Thrombin Solution
  •  Thrombin (Human): 400 – 625 units/mL* Calcium Chloride: 36 – 44 µmol/mLOther ingredients include: human albumin, sodium chloride and water for injection.
  •  * The potency expressed in units is determined with a clotting assay using an in-house internal standard that has been calibrated against the World Health Organization (WHO) Second International Standard for Thrombin, 01/580. Therefore, a unit (U) is equivalent to an International Unit (IU).

Viral Clearance TISSEEL is made from pooled human plasma collected at US licensed collection centers. The vapor heat and solvent/detergent treatment steps used in the manufacturing process have been shown to be capable of significant viral reduction. No procedure, however, has been shown to be completely effective in removing viral infectivity from derivatives of human plasma (see Warnings and Precautions (5.5) ). Validation studies were conducted using samples drawn from manufacturing intermediates for each of the two human plasma derived components. These samples were spiked with stock virus suspensions of known titers followed by further processing under conditions representative of respective manufacturing steps.

The virus reduction factors (expressed as log10) of manufacturing steps for each of the viruses tested are shown in Table 6.
Table 6: Reduction Factors for Virus Removal and/or Inactivation

Sealer Protein Component

Manufacturing Step

Mean Reduction Factors [log10] of Virus Tested

HIV-1

HAV

BVDV

PRV

MMV

Early Manufacturing Steps

n.d.

n.d.

n.d.

n.d.

2.7

Solvent/Detergent Treatment

>5.3

n.d.

>5.7

>5.9

n.d.

Vapor Heat Treatment

>5.5

>5.6

>5.7

>6.7

1.2

Overall Reduction Factor (ORF)

>10.8

>5.6

>11.4

>12.6

3.9

Thrombin Component

Manufacturing Step

Mean Reduction Factors [log10] of Virus Tested

HIV-1

HAV

BVDV

PRV

MMV

Thrombin Precursor Mass Capture

3.2

1.5

1.8

2.5

1.2

Vapor Heat Treatment

>5.5

>4.9

>5.3

>6.7

1.0

Solvent/Detergent Treatment

>5.3

n.d.

>5.5

>6.4

n.d.

Ion Exchange Chromatography

n.d.

n.d.

n.d.

n.d.

3.6

Overall Reduction Factor (ORF)

>14.0

>6.4

>12.6

>15.6

5.8

n.d. = not determined

HIV-1: Human Immunodeficiency Virus 1; HAV: Hepatitis A Virus; BVDV: Bovine Viral Diarrhea Virus, a model for Hepatitis C Virus; PRV: Pseudorabies Virus, a model for lipid enveloped DNA viruses, among those is Hepatitis B Virus; MMV: Mouse Minute Virus, a model for B19V.

In addition, Human Parvovirus B19 (B19V) was used to investigate the upstream Thrombin precursor mass capture step, the Sealer Protein early manufacturing steps and the Thrombin and Sealer Protein vapor heating steps. Using quantitative PCR assays, the estimated B19V log reduction factors were: (a) 1.7 for the Thrombin precursor mass capture step, (b) 3.4 for Sealer Protein early manufacturing steps, (c) >4 for Thrombin vapor heat treatment and (d) 1.0 for Sealer Protein vapor heat treatment.

12 Clinical Pharmacology


12.1 Mechanism of Action


Upon mixing Sealer Protein (Human) and Thrombin (Human), soluble fibrinogen is transformed into fibrin, forming a rubber-like mass that adheres to the wound surface and achieves hemostasis and sealing or gluing of tissues. TISSEEL mimics the final coagulation cascade step as it has all relevant components to form a clot. TISSEEL is effective in heparinized patients and in patients medicated with anti-platelet drugs.

12.2 Pharmacodynamics


Thrombin is a highly specific protease that transforms the fibrinogen contained in Sealer Protein (Human) into fibrin. Fibrinolysis inhibitor, Aprotinin (Synthetic), is a polyvalent protease inhibitor that prevents premature degradation of fibrin. Preclinical studies with different fibrin sealant preparations simulating the fibrinolytic activity generated by extracorporeal circulation in patients during cardiovascular surgery have shown that incorporation of aprotinin in the product formulation increases resistance of the fibrin sealant clot to degradation in a fibrinolytic environment.

12.3 Pharmacokinetics


Unincorporated Aprotinin and its metabolites have a half-life of 30 to 60 minutes and are eliminated by the kidney. Pharmacokinetic studies were not conducted. TISSEEL is expected to be completely resorbed in 10 to14 days

Because TISSEEL is applied only topically, systemic exposure or distribution to other organs or tissues is not expected.

13 Nonclinical Toxicology


13.1 Carcinogenesis, Mutagenesis, Impairment of Fertility


Long-term animal studies to evaluate the carcinogenic potential of TISSEEL or studies to determine the effect of TISSEEL on fertility have not been performed.

14 Clinical Studies


14.1 Vascular Surgery


TISSEEL was evaluated in a prospective, controlled, randomized, single-blind, multicenter clinical study against manual compression with gauze pads in 140 subjects undergoing vascular surgery with expanded polytetrafluoroethylene (ePFTE) graft placement (arterio-arterial bypasses and AV shunts for dialysis access in the upper and lower extremity). Subjects received standardized dosages of heparin. Protamine was administered after the primary endpoint had been assessed. Long-term antiplatelet treatments were continued perioperatively at the surgeon’s discretion.

Subjects were randomly assigned to TISSEEL or control when persistent bleeding at the study suture line was present after surgical hemostasis, i.e., sutures. Eligible bleedings before clamping and treatment application were defined as a minimum of 25% of the suture line bleeds or at least 5 suture line bleedings or any pulsatile or spurting needle hole bleeding. For the primary endpoint, hemostasis achieved at the study suture line at 4 minutes and maintained until surgical closure, a single application of TISSEEL was statistically significantly superior to control (p<0.0001; likelihood ratio chi-square test; 2.5% one sided) [ITT].
Table 7: Vascular Surgery

Hemostasis at the study suture line within 4 minutes and maintained until surgical closure

TISSEEL

Manual Compression

Intent to Treat Analysis

44/70 (62.9%)

22/70 (31.4%)

14.2 Cardiac Surgery


TISSEEL was evaluated in a prospective, parallel design, randomized (1:1), double-blind, multicenter clinical study against an earlier formulation of the product, TISSEEL VH, in 317 subjects undergoing cardiac surgery requiring cardiopulmonary bypass (CPB) and median sternotomy. Patients were treated with TISSEEL or the control product only when hemostasis was not achieved by conventional surgical methods. For the endpoint, hemostasis achieved at the primary treatment site within 5 minutes of treatment and maintained until closure of the surgical wound, TISSEEL was non-inferior to the earlier formulation of the product using a one-sided 97.5% confidence interval on the difference in the proportion of subjects successfully treated.
Table 8: Cardiac Surgery

Hemostasis within 5 minutes and maintained until surgical closure

TISSEEL

TISSEEL VH

Intent to Treat Analysis

127/144 (88.2%)

129/144 (89.6%)

14.3 Cardiac Reoperations


An earlier formulation of TISSEEL was evaluated in an open-label crossover study against control topical hemostatic agents in 489 patients undergoing cardiovascular reoperation or resternotomy at 11 institutions. Patients were randomized to TISSEEL or control hemostatic agents when a topical hemostatic was needed at the conclusion of surgery and after all attempts at surgical hemostasis. Patients were crossed to the alternative therapy if bleeding continued after the 5 minute endpoint. At 10 centers, TISSEEL was used after administration of protamine sulfate. At one site, TISSEEL could be used before administration of protamine sulfate. 365 of the 489 patients developed bleeding episodes requiring treatment. For the endpoint (successful hemostasis at 5 minutes), TISSEEL was statistically significantly superior to control topical hemostatic agents in these patients. Similarly, absolute time to cessation of bleeding was statistically significantly shorter for TISSEEL than for control topical hemostatic agents (p<0.0001, Gehan- Wilcoxon test, two sided).
Table 9: Cardiac Reoperations

Hemostasis within 5 minutes

TISSEEL

Control Topical Hemostatic Agent

82.4% (159/193)

44.5% (76/172)

Pearson χ2 two sided; p <0.0001; intent-to-treat analysis

14.4 Splenectomy


In a single center, open label trial, an earlier formulation of TISSEEL was compared to historical controls in patients undergoing laparotomy for blunt or penetrating traumatic injury to the spleen and/or liver. Use of TISSEEL resulted in the need for statistically significantly fewer splenectomies than control hemostatic maneuvers (Refer to Table 9). TISSEEL did not result in significantly reduced mortality in patients with blunt or penetrating trauma to the liver alone or to the liver and spleen (p=0.067, χ2, one sided).
Table 10: Splenectomy

Splenectomy Rate

Injury to:

TISSEEL

Historic Controls

Spleen

0/19

14/22

p <0.001

Spleen and liver

1/26

19/34

p <0.001

14.5 Colostomy Closure


In a single center, prospective open label study of 118 patients randomized to standard of care (58 patients) or standard of care plus fibrin sealant (60 patients) for elective colostomy closure after temporary colostomy placement for treatment of traumatic injury to the colon, the earlier version of TISSEEL plus standard of care was also shown to be significantly superior to standard of care alone (p=0.0406, Jonckheere-Terpstra test for ordinal data, two sided) with regard to anastomotic complications (leakage, intra-abdominal abscess formation, re-operation, septic shock, and death).

16 How Supplied/storage And Handling


How Supplied

TISSEEL is supplied in the following pack sizes and presentations:
TISSEEL Kit (Freeze-Dried) 0338-4210-02 0338-4211-04 0338-4212-10
Table 11: NDC Numbers

Pack Size
 

TISSEEL Kit (Freeze-Dried)

with DUPLOJECT System

TISSEEL Pre-Filled AST Syringe

(Frozen) with

DUO Set

TISSEEL Pre-Filled PRIMA Syringe (Frozen) with DUPLOJECT COMBI

2 mL
 

0338-4301-02

0338-8402-02

0338-9560-01

4 mL
 

0338-4302-04

0338-8402-04

0338-9564-01

10 mL
 

0338-4303-10

0338-8402-10

0338-9568-01

TISSEEL Kit contains one vial each of:
  • 1.Sealer Protein Concentrate (Human), Vapor Heated, Solvent/Detergent Treated, Freeze-Dried, Sterile
  • 2.Fibrinolysis Inhibitor Solution, (Synthetic) Liquid, Sterile
  • 3.Thrombin (Human), Vapor Heated, Solvent/Detergent Treated, Freeze-Dried, Sterile
  • 4.Calcium Chloride Solution, Liquid, Sterile

TISSEEL Pre-Filled Dual-Chambered Syringe contains:
  • 1.Sealer Protein Solution, Vapor Heated, Solvent/Detergent Treated, Frozen Solution, Sterile
  • 2.Thrombin Solution, Vapor Heated, Solvent/Detergent Treated, Frozen Solution, Sterile
  • 3.Sterile accessory devices (DUO Set and Plunger or DUPLOJECT COMBI)

Storage and Handling TISSEEL Kit (Freeze-Dried) Store at 2-25°C. Avoid freezing. Do not freeze or refrigerate reconstituted solutions.

TISSEEL Pre-filled Syringe (Frozen) Store at ≤ -20°C. Do not refrigerate or re-freeze after thawing. Once removed from the freezer, TISSEEL must be used within 48 hours. Prior to application, TISSEEL must be warmed to 33 - 37˚C.Once the pouches are opened or warmed to 33-37°C, they must be used within 4 hours. Do not use after the expiration date. Discard if packaging of any components is damaged.

17 Patient Counseling Information


Discuss the risks and benefits of this product with the patient since it is made from human plasma.

Instruct patients to consult their physician if symptoms of B19 virus infection appear (fever, drowsiness, chills and runny nose) followed about two weeks later by a rash and joint pain (see
Use in Specific Populations (8.1)
).


Manufactured For Baxter Healthcare Corporation Deerfield, IL 60015 USA US License No. 140

Baxter, Artiss, Duo, Duploject, Duploject Combi, Duplospray, Easyspray, Fibrinotherm and Tisseel are trademarks of Baxter International Inc.

Package/label Principal Display Panel

Tiseel Frozen 2 mL AST Pouch Label
Fibrin SealantTISSEEL 2 mL

NDC 0338-8402-01

Vapor Heated, Solvent/Detergent Treated, Frozen

Baxter Logo

Temperature sensitive – Do NOT expose above 37°C (99°F).

TOPICAL USE ONLY DO NOT INJECT

Read directions for thawing and application before use.

Store at –20°C (–4°F) or colder. Unopened pouches may bestored for up to 48 hours at room temperature (15 – 25°C).

Do not refrigerate or re-freeze.

Rx Only

Contents:

Pre-filled syringe containing:

– Sealer Protein Solution (1): 1 mL, sterile– Sealer Protein (Human)– Fibrinolysis Inhibitor (Aprotinin, Synthetic), 3000 KIU/mL

– Thrombin Solution (2): 1 mL, sterile– Thrombin (Human), 500 units/mL– Calcium Chloride, 40 μmol/mL

DMC

Manufactured forBaxter HealthcareCorporation Deerfield, IL 60015 USA

U.S. License No. 1400736623

Lot No.:

Exp. Date:

P
Tisseel Frozen 2 mL AST Carton Label
0736624

Fibrin Sealant TISSEEL

Vapor Heated, Solvent/Detergent Treated, Frozen

TOPICAL USE ONLY

2 mL

N3 0338-8402-02 3

Fibrin Sealant TISSEEL

TOPICAL USE ONLY

2 mL

Fibrin Sealant TISSEEL

Vapor Heated, Solvent/Detergent Treated, Frozen

NDC 0338-8402-02

Prefilled Syringe

2 mL

TOPICAL USE ONLY

Contents:Pre-filled syringe containing:

Sealer Protein Solution: 1 mL, sterile– Sealer Protein (Human)– Fibrinolysis Inhibitor (Aprotinin, Synthetic), 3000 KIU/mL

Thrombin Solution: 1 mL, sterile– Thrombin (Human), 500 units/mL– Calcium Chloride, 40 μmol/mL

The risks and benefits of this product should be discussed with the patient.

Rx Only

DO NOT INJECT

Store at –20°C (–4°F) or colder.

Read enclosed directions for thawing and application before use.

Unopened pouches may be stored for up to 48 hours at roomtemperature (15 – 25°C).

Do not refrigerate or re-freeze.

Not made with natural rubber latex

For Single Use Only.

Baxter Logo

Fibrin Sealant TISSEEL

TOPICAL USE ONLY

2 mL

Fibrin Sealant TISSEEL

TOPICAL USE ONLY

2 mL

Baxter Logo

736624

Fibrin Sealant TISSEEL

Vapor Heated, Solvent/Detergent Treated, Frozen

Pre-filled Syringe

2 mL

TOPICAL USE ONLYDO NOT INJECT

U.S. Pat. No.: 5,962,405

Manufactured for Baxter Healthcare Corporation Deerfield IL, 60015 USA1-888-229-0001U.S. License No. 140Made in Austria

Reorder Number: 1501261

Baxter and Tisseel are trademarks of Baxter International Inc.

Baxter Logo
Tissel Lyo 2 mL Vial Carton Label
NDC 0338-4210-02

Fibrin SealantTISSEEL 2 mLVapor Heated, Solvent/Detergent Treated, Kit

GTIN (01)LOT (10)EXPIRY (17)SERIAL (21)

Baxter Logo

NDC 0338-4210-02

Barcode

Fibrin SealantTISSEEL 2 mLVapor Heated, Solvent/Detergent Treated, Kit

Contents:

Sealer Protein Concentrate (Human), Vapor Heated,Solvent/Detergent Treated, freeze dried, sterile, for1 mL of Sealer Protein Solution 86.5 mg/mL

Fibrinolysis Inhibitor Solution (Synthetic), sterile,3000 KIU of Aprotinin /mL

Thrombin (Human), Vapor Heated, Solvent/DetergentTreated, freeze dried, sterile, for 1 mL of ThrombinSolution 500 units/mL

Calcium Chloride Solution, sterile, 40 μmol /mL

The risks and benefits of this product should be discussedwith the patient.Read enclosed directions for reconstitution and applicationbefore use.Use within four hours of reconstitution.

NOT FOR INJECTION. For single use only.

Not made with natural rubber latex

Rx only

Manufactured for Baxter Healthcare Corporation Deerfield, IL 60015 USA

U.S. License No. 140

Made in Austria

U.S. Pat. No.: 5,962,405

Baxter and Tisseel are trademarks of Baxter International Inc.

0752668

Fibrin SealantTISSEEL 2 mLVapor Heated, Solvent/Detergent Treated, Kit

2 mL

Store at 2°C to 25°C (36°F to 77°F).Avoid freezing.
Tisseel Lyo 2mL Sleeve Carton Label
Baxter Logo

NDC 0338-4301-02

Fibrin SealantTISSEEL 2 mLVapor Heated, Solvent/Detergent Treated, Kit

Manufactured for Baxter Healthcare Corporation Deerfield, IL 60015 USA

U.S. License No. 140

Made in Austria

Reorder Number: 1504514

Baxter, Duploject and Tisseel are trademarks of Baxter International Inc.

U.S. Pat. No.: 5,962,405

Baxter Logo

NDC 0338-4301-02

Fibrin SealantTISSEEL 2 mLVapor Heated, Solvent/Detergent Treated, Kit

TOPICAL USE ONLYDO NOT INJECT

Baxter Logo

NDC 0338-4301-02

Barcode

Fibrin SealantTISSEEL 2 mLVapor Heated, Solvent/Detergent Treated, Kit

Contents:

Sealer Protein Concentrate (Human), Vapor Heated, Solvent/Detergent Treated, freeze dried, sterile, for1 mL of Sealer Protein Solution 86.5 mg/mL

Fibrinolysis Inhibitor Solution (Synthetic), sterile,3000 KIU of Aprotinin /mL

Thrombin (Human), Vapor Heated, Solvent /DetergentTreated, freeze dried, sterile, for 1 mL of Thrombin Solution500 units/mL

Calcium Chloride Solution, sterile, 40 μmol /mL

The risks and benefits of this product should be discussedwith the patient. Read enclosed directions forreconstitution and application before use. Use within fourhours of reconstitution.

NOT FOR INJECTION. For single use only.

Not made with natural rubber latexRx only

Also includes: DUPLOJECT Fibrin Sealant Preparation and Application System 2 mL / 4 mL

0752670

Barcode

BarcodeN3 0338-4301-02 3
Tisseel Frozen 2 mL – 4 mL DUO Set Label
Baxter Label

DUO Set 2 ml / 4ml

Indications for Use:

For the application of TISSEEL Fibrin Sealant

For single use only. Not made with natural rubber latex.

Do not reuse or resterilize. Sterilized by gamma radiation.

Sterile and non-pyrogenic in unopened and undamaged package.

Rx only.

Lot No:

Exp. Date:

REF

BE-90-01-040

Manufactured for: Baxter Healthcare Corporation, One Baxter ParkwayDeerfield, IL 60015 USA

Made in Belgium
Tisseel Lyo 2 mL - 4 mL DUPLOJET Label
Baxter Logo

DUPLOJET 2 mL / 4 mL

Fibrin Sealant Preparation and Application System

Baxter Logo

DUPLOJET 2 mL / 4 mL

Fibrin Sealant Preparation and Application System

BAXTER, DUPLOJET and TISSEEL are trademarks ofBaxter International Inc., registered in the U.S. Patent andTrademark office.

Manufactured for: Baxter Healthcare Corporation One Baxter ParkwayDeerfield, IL 60015 USA

DUPLOJET 2 mL / 4 mLFibrin Sealant Preparation andApplication System

For Fibrin Sealant2 mL or 4 mL Kit

2 mL4 mL

Indications for Use:For the preparation and application of TISSEEL[Fibrin Sealant] 2 mL / 4 mL Kit.

STERILE – SINGLE PATIENT USE ONLY – DO NOT RESTERILIZE

Use separate devices for reconstruction of Sealer Protein Concentrateand Thrombin.

Rx only

Made in Belgium

Barcode

BE8001137

BE-80-01-137

DUPLOJET 2 mL / 4 mLFibrin Sealant Preparation andApplication System

For Fibrin Sealant2 mL or 4 mL Kit

2 mL4 mL
DUPLOJET IFU Label
Baxter Logo BE_30-02-680

DUPLOJECTFibrin Sealant Preparation and Application System

Indications for Use:

For the preparation and application of TISSEEL [Fibrin Sealant] kit.

Note: See TISSEEL Fibrin Sealant package insert for additional preparation andapplication instructions.

1.0 Reconstitution Instructions for the Circulating Nurse (Using the FIBRINO-THERM Heating and Stirring Device)

1.1 Turn on the warming unit of the FIBRINOTHERM device (amber switch).

1.2 Open TISSEEL [Fibrin Sealant] kit and place all vials into the appropriately sized heating wells of the FIBRINOTHERM device.

1.3 Place the Sealer Protein vial into the large magnetic stirring well fitted with the appropriately sized adapter ring (if necessary). Do not activate the stirring mechanism at this time. The indicator light will remain lit until a temperature of37°C (98.6°F) is reached. Allow several minutes for proper warming.

1.4 Open Pack A of the DUPLOJECT Preparation and Application System andassemble the blue-scaled and black-scaled syringes with the needles provided.

1.5 Remove the flip-off caps from the blue-capped Sealer Protein Concentrateand Fibrinolysis Inhibitor Solution vials and wipe with a non-iodine based dis-infectant.

1.6 Using the blue-scaled syringe, withdraw the Fibrinolysis Inhibitor Solution from the vial, tilting the vial slightly to facilitate removal of all solution. Inject the Fibrinolysis Inhibitor Solution into the Sealer Protein Concentrate vial. Gentlyswirl the vial to ensure that the freeze-dried material is fully soaked. Note: Do not invert or inject air into vials.

1.7 Place the Sealer Protein Concentrate vial in the stirring well and activate the stirring mechanism of the FIBRINOTHERM device (green switch). Reconstitutionis complete when no undissolved particles are visible. If Sealer Protein is not fully dissolved after 20 minutes, discard and prepare a fresh kit. Continue with steps 8through 11.

1.8 Remove the flip-off caps from the black-capped Thrombin and Calcium ChlorideSolution vials and wipe with a non-iodine based disinfectant.

1.9 Using the black-scaled syringe, withdraw the Calcium Chloride Solution from thevial, tilting the vial slightly to facilitate removal of all solution. Inject the CalciumChloride Solution into the Thrombin vial. Note: Do not invert or inject air into vials.

1.10 Swirl contents of the Thrombin vial briefly and return it to an appropriately sizedheating well in the FIBRINOTHERM device.

1.11 Leave the Sealer Protein and Thrombin vials in the FIBRINOTHERM device untilthe solutions are ready to be passed into the sterile field.

2.0 Preparation Instructions for the Scrub Nurse

2.1 Open Pack B of the DUPLOJECT Preparation and Application System into thesterile field.

2.2 Open Packs 1, 2, and 3.

2.3 Assemble the blue-scaled and black-scaled syringes with the needles provided.Note: For 5 mL DUPLOJECT systems, attach the larger needle to the blue-scaledsyringe.

2.4 While the Circulating Nurse holds the vial slightly tilted, insert needle intovial (bevel side down) and withdraw all of the Sealer Protein Solution into theblue-scaled syringe using slow, constant aspiration. Discard needle in sharpscontainer.

2.5 While the Circulating Nurse holds the vial slightly tilted, insert needle into vial(bevel side down) and withdraw all of the Thrombin Solution into the black-scaledsyringe using slow, constant aspiration. Discard needle in sharps container.

2.6 Remove any air bubbles from the syringes and ensure both syringes contain the same volume.

2.7 Snap the filled syringes into the two-syringe clip with the flanges in an up/downposition, as illustrated below.

2.8 Attach the joining piece to the syringe nozzles, ensuring that both are firmlyseated. Secure the joining piece by fastening the retaining strap to the doublesyringe clip. Note: Align the syringe nozzles toward the middle for properattachment.

2.9 Fit one of the application needles onto the joining piece. A second applicationneedle is provided in Pack 3 as a spare.

2.10 DUPLOJECT Applicator is ready for use.

2.11 If application of TISSEEL [Fibrin Sealant] is interrupted, replace the needleimmediately before application is resumed. Note: If the apertures of the joiningpiece become clogged, Pack 4 contains one spare joining piece and two additional application needles.

Rx OnlyDO NOT REUSE OR RESTERILIZE.NOT MADE WITH NATURAL RUBBER LATEX.

STERILE AND NON-PYROGENIC IN UNOPENED AND UNDAMAGED PACKAGE.

DISPOSE OF CONTAMINATED AND SHARP COMPONENTS PROPERLY.

Baxter, Duploject, Fibrinotherm and Tisseel are registered trademarks of Baxter International Inc.

Manufactured for: Baxter Healthcare Corporation One Baxter Parkway Deerfield, IL 60015 USA 1-888-229-0001

Made in Belgium

Rev. Date: 2017-05-17
2 mL PRIMA Pouch Label
Fibrin SealantTISSEEL 2 mL

NDC 0338-9560-01

Vapor Heated, Solvent/Detergent Treated, Frozen

Baxter Logo

Temperature sensitive – Do NOT expose above 37°C (99°F).

TOPICAL USE ONLY DO NOT INJECT

Read directions for thawing and application before use.Store at –20°C (–4°F) or colder. Unopened pouchesmay be stored for up to 48 hours at room temperature (15 – 25°C).

Do not refrigerate or re-freeze.

Rx Only

Contents: Pre-filled syringe containing:– Sealer Protein Solution (1): 1 mL, sterile – Fibrinogen (Human), 86.5 mg/mL– Fibrinolysis Inhibitor (Aprotinin,Synthetic), 3000 KIU/mL

– Thrombin Solution (2): 1 mL, sterile– Thrombin (Human), 500 units/mL– Calcium Chloride, 40 ìmol/mL

Manufactured forBaxter HealthcareCorporation Deerfield, IL 60015 USAU.S. License No. 1400752652

Barcode

Lot No.:Exp. Date:
2 mL PRIMA Carton Label
0752653

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY

NDC 0338-9560-01Barcode

Barcode3 03389 56001 2

2 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, Frozenwith Pre-filled PRIMA Syringe

TOPICAL USE ONLY

Contents:Pre-filled syringe containing:Sealer Protein Solution: 1 mL, sterile

– Fibrinogen (Human), 86.5 mg/mL– Fibrinolysis Inhibitor (Aprotinin, Synthetic),3000 KIU/mL

Thrombin Solution: 1 mL, sterile– Thrombin (Human), 500 units/mL– Calcium Chloride, 40 μmol /mL

The risks and benefits of this product shouldbe discussed with the patient.

Rx Only

DO NOT INJECT

Store at –20°C (–4°F) or colder.

Read enclosed directions for thawing andapplication before use.

Unopened pouches may be stored for up to48 hours at room temperature (15 – 25°C).

Do not refrigerate or re-freeze.

Not made with natural rubber latexFor Single Patient Use Only.

NDC 0338-9560-01

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY2 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY2 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY2 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, Frozenwith Pre-filled PRIMA Syringe

TOPICAL USE ONLY

DO NOT INJECT

U.S. Pat. No.: 5,962,405

Manufactured for Baxter Healthcare Corporation

Deerfield IL, 60015 USA

1-888-229-0001

U.S. License No. 140

Made in Austria

Reorder Number: 1506078

Baxter and Tisseel are trademarks ofBaxter International Inc.

2 mL

GTIN (01) 00303389560012

EXPIRY (17)LOT (10)SERIAL (21)

Baxter Logo

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY2 mL
4 mL PRIMA Pouch Label
Fibrin SealantTISSEEL 4 mL

NDC 0338-9564-01Barcode

Vapor Heated, Solvent/Detergent Treated, Frozen

Baxter Logo

Temperature sensitive – Do NOT expose above 37°C (99°F).

TOPICAL USE ONLY DO NOT INJECT

Read directions for thawing and application before use.Store at –20°C (–4°F) or colder. Unopened pouchesmay be stored for up to 48 hours at room temperature (15 – 25°C).

Do not refrigerate or re-freeze.

Rx Only

Contents: Pre-filled syringe containing:– Sealer Protein Solution (1): 2 mL, sterile– Fibrinogen (Human), 86.5 mg/mL– Fibrinolysis Inhibitor (Aprotinin,Synthetic), 3000 KIU/mL

– Thrombin Solution (2): 2 mL, sterile– Thrombin (Human), 500 units/mL– Calcium Chloride, 40 µmol/mL

Barcode

Manufactured forBaxter HealthcareCorporation Deerfield, IL 60015 USAU.S. License No. 140

0752656

Barcode

Lot No.:Exp. Date:
4 mL PRIMA Carton Label
0752657

Barcode3 03389 56401 0

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLYwith Pre-filled PRIMA Syringe

NDC 0338-9564-01

TOPICAL USE ONLY

Contents:Pre-filled syringe containing:Sealer Protein Solution: 2 mL, sterile– Fibrinogen (Human), 86.5 mg/mL– Fibrinolysis Inhibitor (Aprotinin, Synthetic),3000 KIU/mL

Thrombin Solution: 2 mL, sterile– Thrombin (Human), 500 units/mL– Calcium Chloride, 40 μmol /mL

The risks and benefits of this product shouldbe discussed with the patient.

Rx Only

DO NOT INJECT

Store at –20°C (–4°F) or colder.

Read enclosed directions for thawing andapplication before use.

Unopened pouches may be stored for up to48 hours at room temperature (15 – 25°C).

Do not refrigerate or re-freeze.

Not made with natural rubber latexFor Single Patient Use Only.

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY4 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY4 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY4 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, Frozenwith Pre-filled PRIMA Syringe

TOPICAL USE ONLY

DO NOT INJECT

U.S. Pat. No.: 5,962,405

Manufactured for Baxter Healthcare Corporation

Deerfield IL, 60015 USA

1-888-229-0001

U.S. License No. 140

Made in Austria

Reorder Number: 1506079

Baxter and Tisseel are trademarks ofBaxter International Inc.

4 mL

Baxter Logo

GTIN (01) 00303389564010LOT (10)EXPIRY (17)SERIAL (21)
10 mL PRIMA Pouch Label
Fibrin SealantTISSEEL 10 mL

NDC 0338-9568-01

Vapor Heated, Solvent/Detergent Treated, Frozen

Baxter Logo

Temperature sensitive – Do NOT expose above 37°C (99°F).

TOPICAL USE ONLY DO NOT INJECT

Read directions for thawing and application before use.

Store at –20°C (–4°F) or colder. Unopened pouchesmay be stored for up to 48 hours at room temperature (15 – 25°C).

Do not refrigerate or re-freeze.

Rx Only

Contents:

Pre-filled syringe containing: – Sealer Protein Solution (1): 5 mL, sterile– Fibrinogen (Human), 86.5 mg/mL– Fibrinolysis Inhibitor (Aprotinin, Synthetic), 3000 KIU/mL

– Thrombin Solution (2): 5 mL, sterile– Thrombin (Human), 500 units/mL– Calcium Chloride, 40 ìmol/mL

Manufactured forBaxter HealthcareCorporation Deerfield, IL 60015 USAU.S. License No. 140

0752660

Barcode

Barcode

Lot No.:Exp. Date:
10mL PRIMA Carton Label
0752661

Barcode3 03389 56801 8

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY

NDC 0338-9568-01Barcode

10 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY

10 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, Frozenwith Pre-filled PRIMA Syringe

TOPICAL USE ONLY

Contents:Pre-filled syringe containing:Sealer Protein Solution: 5 mL, sterile– Fibrinogen (Human), 86.5 mg/mL– Fibrinolysis Inhibitor (Aprotinin, Synthetic),3000 KIU/mL

Thrombin Solution: 5 mL, sterile– Thrombin (Human), 500 units/mL– Calcium Chloride, 40 μmol /mL

The risks and benefits of this product shouldbe discussed with the patient.

Rx Only

DO NOT INJECT

Store at –20°C (–4°F) or colder.

Read enclosed directions for thawing andapplication before use.

Unopened pouches may be stored for up to48 hours at room temperature (15 – 25°C).

Do not refrigerate or re-freeze.

Not made with natural rubber latex

For Single Patient Use Only

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY

10 mL

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, FrozenTOPICAL USE ONLY10 mL

Barcode

Fibrin SealantTISSEELVapor Heated, Solvent/Detergent Treated, Frozenwith Pre-filled PRIMA Syringe

TOPICAL USE ONLY

DO NOT INJECT

U.S. Pat. No.: 5,962,405

Manufactured for Baxter Healthcare Corporation

Deerfield IL, 60015 USA

1-888-229-0001

U.S. License No. 140

Made in Austria

Reorder Number: 1506080

Baxter and Tisseel are trademarks ofBaxter International Inc.

10 mL

Baxter Logo

GTIN (01) 00303389568018EXPIRY (17)LOT (10)SERIAL (21)
Lyo 4mL Vial Carton Label
GTIN (01)LOT (10)EXPIRY (17)

SERIAL (21)

NDC 0338-4211-04

Fibrin SealantTISSEEL 4 mLVapor Heated, Solvent/Detergent Treated, Kit

Baxter logo

NDC 0338-4211-04barcode

Fibrin SealantTISSEEL 4 mLVapor Heated, Solvent/Detergent Treated, Kit

Contents: Sealer Protein Concentrate (Human), Vapor Heated,Solvent /Detergent Treated, freeze dried, sterile, for2 mL of Sealer Protein Solution Fibrinolysis Inhibitor Solution (Synthetic), sterile,3000 KIU of Aprotinin /mL Thrombin (Human), Vapor Heated, Solvent /DetergentTreated, freeze dried, sterile, for 2 mL of ThrombinSolution 500 units/mL Calcium Chloride Solution, sterile, 40 μmol /mL

The risks and benefits of this product should be discussedwith the patient.Read enclosed directions for reconstitution and applicationbefore use.Use within four hours of reconstitution. NOT FOR INJECTION. For single use only. Not made with natural rubber latexRx only

Manufactured for Baxter Healthcare Corporation Deerfield, IL 60015 USA

U.S. License No. 140

Made in Austria

Baxter and Tisseel are trademarks of Baxter International Inc.

U.S. Pat. No.: 5,962,405

Barcode0752678

Fibrin SealantTISSEEL 4 mLVapor Heated, Solvent/Detergent Treated, Kit

4 mL

Store at 2°C to 25°C (36°F to 77°F).Avoid freezing.
Lyo 10mL Vial Carton Label
GTIN (01)LOT (10)EXPIRY (17)

SERIAL (21)

NDC 0338-4212-10

Fibrin SealantTISSEEL 10 mLVapor Heated, Solvent/Detergent Treated, Kit

Baxter Logo

NDC 0338-4212-10barcode

Fibrin SealantTISSEEL 10 mLVapor Heated, Solvent/Detergent Treated, Kit

Contents: Sealer Protein Concentrate (Human), Vapor Heated,Solvent /Detergent Treated, freeze dried, sterile, for5 mL of Sealer Protein Solution 86.5 mg/mL

Fibrinolysis Inhibitor Solution (Synthetic), sterile,3000 KIU of Aprotinin /mL

Thrombin (Human), Vapor Heated, Solvent /DetergentTreated, freeze dried, sterile, for 5 mL of ThrombinSolution 500 units/mL

Calcium Chloride Solution, sterile, 40 µmol /mL

The risks and benefits of this product should be discussedwith the patient.Read enclosed directions for reconstitution and applicationbefore use.Use within four hours of reconstitution.

NOT FOR INJECTION. For single use only.

Not made with natural rubber latex

Rx only

Manufactured for Baxter Healthcare Corporation Deerfield, IL 60015 USA

U.S. License No. 140

Made in Austria

Baxter and Tisseel are trademarks of Baxter International Inc.

U.S. Pat. No.: 5,962,405

Barcode

0752688

Fibrin SealantTISSEEL 10 mLVapor Heated, Solvent/Detergent Treated, Kit

10 mL

Store at 2°C to 25°C (36°F to 77°F).Avoid freezing.
Lyo 4mL Sleeve Carton Label
Baxter Logo

NDC 0338-4302-04

Fibrin SealantTISSEEL 4 mLVapor Heated, Solvent/Detergent Treated, Kit

Manufactured for Baxter Healthcare Corporation Deerfield, IL 60015 USA

U.S. License No. 140

Made in Austria

Reorder Number: 1504515

Baxter, Duploject and Tisseel are trademarks of Baxter International Inc.

U.S. Pat. No.: 5,962,405

Baxter Logo

NDC 0338-4302-04

Fibrin SealantTISSEEL 4 mLVapor Heated, Solvent/Detergent Treated, Kit

TOPICAL USE ONLYDO NOT INJECT

Baxter Logo

NDC 0338-4302-04barcode

Fibrin SealantTISSEEL 4 mLVapor Heated, Solvent/Detergent Treated, Kit

Contents: Sealer Protein Concentrate (Human), Vapor Heated,Solvent /Detergent Treated, freeze dried, sterile, for2 mL of Sealer Protein Solution 86.5 mg/mL

Fibrinolysis Inhibitor Solution (Synthetic), sterile,3000 KIU of Aprotinin /mL

Thrombin (Human), Vapor Heated, Solvent /DetergentTreated, freeze dried, sterile, for 2 mL of Thrombin Solution500 units/mL

Calcium Chloride Solution, sterile, 40 μmol /mL

The risks and benefits of this product should be discussedwith the patient. Read enclosed directions forreconstitution and application before use. Use within fourhours of reconstitution.

NOT FOR INJECTION. For single use only.

Not made with natural rubber latex

Rx only

Also includes: DUPLOJECT Fibrin Sealant Preparation and Application System 2 mL / 4 mL

0752680

Barcode

BarcodeN3 0338-4302-04 4
Lyo 10mL Sleeve Carton Label
Baxter Logo

NDC 0338-4303-10

Fibrin SealantTISSEEL 10 mLVapor Heated, Solvent/Detergent Treated, Kit

Manufactured for Baxter Healthcare Corporation Deerfield, IL 60015 USA

U.S. License No. 140

Made in Austria

Reorder Number: 1504516

Baxter, Duploject and Tisseel are trademarks of Baxter International Inc.

U.S. Pat. No.: 5,962,405

Baxter Logo

NDC 0338-4303-10

Fibrin SealantTISSEEL 10 mLVapor Heated, Solvent/Detergent Treated, Kit

TOPICAL USE ONLYDO NOT INJECT

Baxter Logo

NDC 0338-4303-10

Barcode

Fibrin SealantTISSEEL 10 mLVapor Heated, Solvent/Detergent Treated, Kit

Contents: Sealer Protein Concentrate (Human), Vapor Heated,Solvent /Detergent Treated, freeze dried, sterile, for5 mL of Sealer Protein Solution 86.5 mg/mL

Fibrinolysis Inhibitor Solution (Synthetic), sterile,3000 KIU of Aprotinin /mL

Thrombin (Human), Vapor Heated, Solvent /DetergentTreated, freeze dried, sterile, for 5 mL of Thrombin Solution500 units/mL

Calcium Chloride Solution, sterile, 40 μmol /mL

The risks and benefits of this product should be discussedwith the patient. Read enclosed directions forreconstitution and application before use. Use within fourhours of reconstitution. NOT FOR INJECTION. For single use only. Not made with natural rubber latexRx only

Also includes: DUPLOJECT Fibrin Sealant Preparation and Application System 10 mL

0752690

Barcode

BarcodeN3 0338-4303-10 2
Duploject Combi Label
Baxter Logo

DuploJect Combi Indication for Use:For the application of TISSEEL Fibrin Sealant.

REF Batch codeUse-by date

For single use only. Not made with natural rubber latex.Do not reuse or resterilize. Sterilized using ethylene oxide.Sterile and non-pyrogenic in unopened and undamaged package. Rx Only.

Manufactured for: Baxter Healthcare Corporation One Baxter ParkwayDeerfield, IL 60015 USA1-888-229-0001

Made in Belgium

BE-90-01-044

DISCLAIMER:

"This tool does not provide medical advice, and is for informational and educational purposes only, and is not a substitute for professional medical advice, treatment or diagnosis. Call your doctor to receive medical advice. If you think you may have a medical emergency, please dial 911."

"Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service."

"This product uses publicly available data from the U.S. National Library of Medicine (NLM), National Institutes of Health, Department of Health and Human Services; NLM is not responsible for the product and does not endorse or recommend this or any other product."

PillSync may earn a commission via links on our site